Synchronized moving aperture radiation therapy (SMART): average tumour trajectory for lung patients
Top Cited Papers
- 17 February 2003
- journal article
- research article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 48 (5), 587-598
- https://doi.org/10.1088/0031-9155/48/5/303
Abstract
Synchronized moving aperture radiation therapy (SMART) is a new technique for treating mobile tumours under development at Massachusetts General Hospital (MGH). The basic idea of SMART is to synchronize the moving radiation beam aperture formed by a dynamic multileaf collimator (DMLC) with the tumour motion induced by respiration. SMART is based on the concept of the average tumour trajectory (ATT) exhibited by a tumour during respiration. During the treatment simulation stage, tumour motion is measured and the ATT is derived. Then, the original IMRT MLC leaf sequence is modified using the ATT to compensate for tumour motion. During treatment, the tumour motion is monitored. The treatment starts when leaf motion and tumour motion are synchronized at a specific breathing phase. The treatment will halt when the tumour drifts away from the ATT and will resume when the synchronization between tumour motion and radiation beam is re-established. In this paper, we present a method to derive the ATT from measured tumour trajectory data. We also investigate the validity of the ATT concept for lung tumours during normal breathing. The lung tumour trajectory data were acquired during actual radiotherapy sessions using a real-time tumour-tracking system. SMART treatment is simulated by assuming that the radiation beam follows the derived ATT and the tumour follows the measured trajectory. In simulation, the treatment starts at exhale phase. The duty cycle of SMART delivery was calculated for various treatment times and gating thresholds, as well as for various exhale phases where the treatment begins. The simulation results show that in the case of free breathing, for 4 out of 11 lung datasets with tumour motion greater than 1 cm from peak to peak, the error in tumour tracking can be controlled to within a couple of millimetres while maintaining a reasonable delivery efficiency. That is to say, without any breath coaching/control, the ATT is a valid concept for some lung tumours. However, to make SMART an efficient technique in general, it is found that breath coaching techniques are required.Keywords
This publication has 22 references indexed in Scilit:
- Three-dimensional intrafractional movement of prostate measured during real-time tumor-tracking radiotherapy in supine and prone treatment positionsInternational Journal of Radiation Oncology*Biology*Physics, 2002
- The effectiveness of breath-holding to stabilize lung and pancreas tumors during radiosurgeryInternational Journal of Radiation Oncology*Biology*Physics, 2002
- Evaluation of respiratory movement during gated radiotherapy using film and electronic portal imagingInternational Journal of Radiation Oncology*Biology*Physics, 2002
- Motion adaptive x-ray therapy: a feasibility studyPhysics in Medicine & Biology, 2000
- Technical aspects of the deep inspiration breath-hold technique in the treatment of thoracic cancerInternational Journal of Radiation Oncology*Biology*Physics, 2000
- Compatibility of Varian 2100C gated operations with enhanced dynamic wedge and IMRT dose deliveryMedical Physics, 2000
- Respiratory gated irradiation system for heavy-ion radiotherapyInternational Journal of Radiation Oncology*Biology*Physics, 2000
- Breathing‐synchronized radiotherapy program at the University of California Davis Cancer CenterMedical Physics, 2000
- Deep inspiration breath-hold technique for lung tumors: the potential value of target immobilization and reduced lung density in dose escalationInternational Journal of Radiation Oncology*Biology*Physics, 1999
- Respiration gated radiotherapy treatment: a technical studyPhysics in Medicine & Biology, 1996