Abstract
The anisotropy of the water diffusion tensor inside brain causes contrast in diffusion images, which depends on the relative orientation of the diffusion gradients and the subject. Because the trace of a tensor is invariant upon rotation, measurement of this trace can reduce the orientation effect. A family of imaging pulse sequences is presented in which the signal intensity is weighted by the trace of the diffusion tensor in a single scan. The methods are demonstrated for chicken gizzard in several orientations with respect to the gradient frame of reference, and for ischemic injury in cat brain after middle cerebral artery occlusion. The sensitivity of the techniques to the presence of background gradients is measured and discussed in detail. As a result, pulse sequences are suggested that provide reliable diffusion constants in both homogeneous and inhomogeneous magnetic fields. The efficiency of the techniques for clinical application is also evaluated.Keywords
This publication has 25 references indexed in Scilit:
- Diffusion-weighted imaging studies of cerebral ischemia in gerbils. Potential relevance to energy failure.Stroke, 1992
- Measuring diffusion in inhomogeneous systems in imaging mode using antisymmetric sensitizing gradientsJournal of Magnetic Resonance (1969), 1992
- Reversible focal ischemic injury demonstrated by diffusion-weighted magnetic resonance imaging in rats.Stroke, 1992
- Mechanism of detection of acute cerebral ischemia in rats by diffusion-weighted magnetic resonance microscopy.Stroke, 1992
- Temporal evolution of ischemic damage in rat brain measured by proton nuclear magnetic resonance imaging.Stroke, 1991
- Restricted and anisotropic displacement of water in healthy cat brain and in stroke studied by NMR diffusion imagingMagnetic Resonance in Medicine, 1991
- Pulsed-gradient spin-echo diffusion studies in nmr imaging. Effects of the imaging gradients on the determination of diffusion coefficientsJournal of Magnetic Resonance (1969), 1990
- Early detection of regional cerebral ischemia in cats: Comparison of diffusion‐ and T2‐weighted MRI and spectroscopyMagnetic Resonance in Medicine, 1990
- A modified pulsed gradient technique for measuring diffusion in the presence of large background gradientsJournal of Magnetic Resonance (1969), 1980
- IMPLICATIONS OF DIFFUSION COEFFICIENT MEASUREMENTS FOR THE STRUCTURE OF CELLULAR WATER*Annals of the New York Academy of Sciences, 1973