Computer-assisted fluoroscopy-based reduction of femoral fractures and antetorsion correction
Open Access
- 1 January 2000
- journal article
- research article
- Published by Taylor & Francis in Computer Aided Surgery
- Vol. 5 (5), 311-325
- https://doi.org/10.1002/1097-0150(2000)5:5<311::aid-igs1>3.0.co;2-j
Abstract
Objective: Intra-operative fluoroscopy is a valuable tool for visualizing underlying bone, implant, and surgical tool positions in orthopedics. It has brought about the minimally invasive surgical technique of intramedullar nailing to fix femoral shaft fractures. However, the limited field of view and two-dimensional property of fluoroscopic images aggravate intra-operative control of surgical parameters. The purpose of this article is to introduce a surgical navigation System based on fluoroscopy that provides missing information for the procedure of femoral fracture fixation. Materials and Methods: Optoelectronic markers are placed on a surgical drill, involved bone fragments, the femoral nail, and the fluoroscope to track their positions. Projection properties of the fluoroscope are acquired through an initial precalibration. The relative positions of bone fragments, implants, and surgical tools are displayed superimposed simultaneously and in real time on multi-planar intra-operative fluoroscopic images. This is achieved by computer simulation of X-ray projections that have taken place with acquisition of the fluoroscopic images. in addition, a method has been developed that allows contactless measurement of three-dimensional anatomic landmarks, based on their representation in fluoroscopic images. in combination with optoelectronic tracking, this enables dynamic calculacion of important surgical parameters such as femoral antetorsion. Results: A pilot surgery showed that fracture reduction can benefit from the developed computer-assisted method. An in-vitro study on computer-assisted measurement of femoral antetorsion demonstrated the high degree of precision of this technique.Keywords
This publication has 15 references indexed in Scilit:
- Surgical navigation based on fluoroscopy?clinical application for computer-assisted distal locking of intramedullary implantsComputer Aided Surgery, 2000
- Fluoroscopy as an Imaging Means for Computer-Assisted Surgical NavigationComputer Aided Surgery, 1999
- Intraoperative control of axes, rotation and length in femoral and tibial fractures technical noteInjury, 1998
- Man-Machine Interfaces in Computer Assisted SurgeryComputer Aided Surgery, 1997
- Femoral shaft fractures treated by intramedullary nailing. A follow-up study focusing on problems related to the methodInjury, 1995
- Computertomographische Torsionswinkel- und Längenmessung an der unteren ExtremitätRöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren, 1992
- Femoral anteversion: Assessment based on function axesJournal of Orthopaedic Research, 1987
- Die computertomographische AntetorsionswinkelbestimmungRöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren, 1986
- Measurement Accuracy of Proximal Femoral Geometry Using Biplanar RadiographyJournal of Pediatric Orthopaedics, 1981
- The Direct Radiographic Measurement of Femoral Torsion Using Axial TomographyPublished by Wolters Kluwer Health ,1972