Laboratory diagnosis ofMycoplasma pneumoniaeinfection: 1. Direct detection of antigen in respiratory exudates by enzyme immunoassay.

Abstract
SUMMARY: Direct and indirect antigen capture enzyme immunoassays (Ag-EIA) have been developed for the detection ofMycoplasma pneumoniaein nasopharyngeal aspirates or sputum from respiratory infection. The sensitivity of the two Ag-EIA were similar, but the indirect method using polyclonal rabbit and guinea-pig antisera was more convenient. The Ag-EIA had a detection limit of 104–4·5colony-forming units/ml of sample. It was specific for M. pneumoniae and gave a low level response with M. genitalium. There were no cross-reactions with 10 other species of mycoplasmas. Tests with a wide range of bacteria and chlamydia group antigen, representing agents sometimes found in the respiratory tract, were also negative. At the current level of development, the Ag-EIA detected about 90% of specimens that were also positive for culture; 43% of specimens from culture-negative-seropositive patients gave a positive result. The overall pattern of results indicated that while antigen detection is a quick and effective substitute for the slow culture method, serological examination for specific IgM antibody is also necessary to give a complete diagnostic coverage.