Intraindividual comparison of higher-order aberrations after implantation of aspherical and spherical intraocular lenses as a function of pupil diameter
- 1 January 2006
- journal article
- research article
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 32 (1), 78-84
- https://doi.org/10.1016/j.jcrs.2005.11.018
Abstract
PURPOSE: To compare intraindividual higher-order wavefront aberrations after implantation of aspherical and spherical intraocular lenses (IOLs) as function of pupil diameter. SETTING: Department of Ophthalmology, Johann Wolfgang Goethe-University, Frankfurt am Main, Germany. METHODS: In this prospective study, wavefront measurements of 21 patients after implantation of a spherical IOL (AMO AR40e) in 1 eye and an aspherical IOL (AMO Tecnis) in the contralateral eye were analyzed. Third-, 4th-, 5th-, total higher-order aberration (HOA) root-mean-square (RMS), and primary spherical aberration (Z40) were compared at different virtual pupil diameters of 3 to 6 mm. RESULTS: For both IOLs and each higher order analyzed, values increased with increasing pupil diameter. Fourth-order RMS and Z40 in the aspherical IOL group were significantly lower than with the spherical IOL at all analyzed pupil diameters. The total HOA RMS of the aspherical IOL was significantly lower than the spherical IOL only at 6 mm pupil diameter. For 3rd- and 5th-order RMS, no significant difference was found between the tested IOLs at any pupil diameter. CONCLUSION: In comparison to a spherical IOL, the aspherical Tecnis IOL reduced Z40 and 4th-order RMS significantly for pupil diameters of 3 to 6 mm, whereas total HOA RMS was only significantly reduced for a pupil diameter of 6 mm.Keywords
This publication has 20 references indexed in Scilit:
- Incision sizes before and after implantation of 6-mm optic foldable intraocular lenses using Monarch and Unfolder injector systemsOphthalmology, 2005
- Aberrationen höherer Ordnung nach Implantation von asphärischen und sphärischen Intraokularlinsen in Abhängigkeit von der PupillenweiteDer Ophthalmologe, 2005
- Effect of intraocular lens optic edge design and material on fibrotic capsule opacification and capsulorhexis contractionJournal of Cataract & Refractive Surgery, 2004
- Improved functional vision with a modified prolate intraocular lensJournal of Cataract & Refractive Surgery, 2004
- Optical aberrations of intraocular lenses measured in vivo and in vitroJournal of the Optical Society of America A, 2003
- Ocular higher-order aberrations in individuals screened for refractive surgeryJournal of Cataract & Refractive Surgery, 2003
- Retinal image contrast and functional visual performance with aspheric, silicone, and acrylic intraocular lensesJournal of Cataract & Refractive Surgery, 2003
- Aberration-correcting intraocular lensesJournal of Cataract & Refractive Surgery, 2003
- Impact of a modified optic design on visual function: Clinical comparative studyJournal of Cataract & Refractive Surgery, 2003
- Design of aspheric intraocular lensesOphthalmic and Physiological Optics, 1991