Screening in early pregnancy for pre‐eclampsia using down syndrome quadruple test markers
- 15 May 2006
- journal article
- research article
- Published by Wiley in Prenatal Diagnosis
- Vol. 26 (6), 559-564
- https://doi.org/10.1002/pd.1459
Abstract
Objectives To estimate the screening performance of early second‐trimester prenatal serum markers for Down syndrome, in screening for the development of pre‐eclampsia, and analyse the uncertainty over its screening performance. Methods A nested case‐control study was carried out on 96 women with pre‐eclampsia and 5 controls for each case from among the women attending three hospitals in London for their prenatal care. Record linkage between computerized obstetric and screening databases identified women with pre‐eclampsia and unaffected control women. The stored frozen serum samples collected from these pregnancies between 15 and 22 weeks' gestation were retrieved and assayed for α‐fetoprotein (AFP), unconjugated estriol (uE3), total human chorionic gonadotrophin (hCG), free β‐hCG and inhibin‐A. Results Pre‐eclampsia was identified from the computerized obstetric records and confirmed by examination of the medical notes. In the pregnancies that went on to develop pre‐eclampsia, early second trimester inhibin‐A and hCG values were significantly raised and uE3 values were significantly lowered, while AFP values were not significantly altered. Using the Quadruple test markers (AFP, uE3, hCG (total or free β) and inhibin‐A), an estimated 34% of pregnancies that developed pre‐eclampsia were detected at a 5% false‐positive rate. If all the women who had pre‐eclampsia in a previous pregnancy (assuming a pre‐eclampsia prevalence of 4%) are considered as screen positive and the serum test is applied to the remaining women, then around 42% of pre‐eclamptic pregnancies would be detected at a 6.5% false‐positive rate. Pre‐eclampsia screening performance using the Quadruple test markers was materially better than that using the Triple test markers. Conclusion Adding screening for pre‐eclampsia to an existing Down syndrome screening programme using the Quadruple test markers is simple and worthwhile. It will detect over 40% of pregnancies with pre‐eclampsia at an acceptable false‐positive rate (about 6%) and with minimal additional costs. Copyright © 2006 John Wiley & Sons, Ltd.Keywords
This publication has 17 references indexed in Scilit:
- Vitamins C and E and the Risks of Preeclampsia and Perinatal ComplicationsNew England Journal of Medicine, 2006
- Quad Screen as a Predictor of Adverse Pregnancy OutcomeObstetrics & Gynecology, 2005
- Screening for pre‐eclampsia by using maternal serum inhibin A, activin A, human chorionic gonadotropin, unconjugated estriol, and alpha‐fetoprotein levels and uterine artery Doppler in the second trimester of pregnancyAustralian and New Zealand Journal of Obstetrics and Gynaecology, 2005
- The pre-eclampsia community guideline (PRECOG): how to screen for and detect onset of pre-eclampsia in the communityBMJ, 2005
- Risk factors for pre-eclampsia at antenatal booking: systematic review of controlled studiesBMJ, 2005
- Vitamin C and E supplementation in women at high risk for preeclampsia: A double-blind, placebo-controlled trialAmerican Journal of Obstetrics and Gynecology, 2005
- Antiplatelet agents for preventing pre-eclampsia and its complicationsPublished by Wiley ,2003
- Correlation Between Second Trimester Maternal Serum Inhibin-A and Human Chorionic Gonadotrophin for the Prediction of Pre-eclampsiaPlacenta, 2000
- Second-trimester levels of maternal serum human chorionic gonadotropin and inhibin a as predictors of preeclampsia in the third trimester of pregnancyJournal of the Society for Gynecologic Investigation, 2000
- Maternal serum screening for Down's syndrome in early pregnancy.BMJ, 1988