Cap Image - ein neuartiges computerunterstütztes Videobildanalysesystem für die dynamische Kapillarmikroskopie - Cap Image - A Newly-developed Computer-aided Videoframe Analysis System for Dynamic Capillaroscopy
- 1 January 1997
- journal article
- abstracts
- Published by Walter de Gruyter GmbH in Biomedizinische Technik/Biomedical Engineering
- Vol. 42 (6), 168-175
- https://doi.org/10.1515/bmte.1997.42.6.168
Abstract
We describe a newly developed multi-function video image analysis system for the computer-aided evaluation of capillaroscopic findings in microcirculation research. The Cap image analysis system comprises an IBM-compatible PC with a Matrox image processing card and real-time video tape digitalization. The video recorder is driven by a personal computer to which it is connected via an RS-232 interface. In contrast to currently available systems, the program presented here makes it possible to select any of several integrated image analysis functions, depending on the quality of the video image. Some examples of the analysis functions available are measurements of erythrocyte flow velocity using the line shift diagram method, the spatial correlation method, and the auto flying spot method. The standard features of the new program include a number of special functions and automatic movement correction. The system thus makes it possible not only to measure numerous morphological parameters such as capillary diameter, length, torquation index and capillary density, but also to perform video densitometric analysis, for example using fluorescent dyes.Keywords
This publication has 7 references indexed in Scilit:
- Synchronous Measurements of Blood Pressure and Red Blood Cell Velocity in Capillaries of Human SkinJournal of Investigative Dermatology, 1996
- Local cold exposure test as therapy control in patients with Raynaud's phenomenon: comparison between laser Doppler fluxmetry and simultaneous red blood cell velocity measurements in nailfold capillariesBritish Journal of Dermatology, 1995
- Entwicklung eines lokalen Kühlverfahrens auf Basis eines thermoelektrischen Peltier-Elements zur erweiterten Kältetestdiagnostik bei akralen ZirkulationsstörungenBiomedizinische Technik/Biomedical Engineering, 1994
- Fehleranalyse, biologische Einflußfaktoren und Varianz der periungualen Videokapillarmikroskopie - Error Analysis, Biological Influencing Factors, and Variance of Periungual Video Capillary MicroscopyBiomedizinische Technik/Biomedical Engineering, 1990
- Zur Methodik der Videokapillarmikroskopie: Bestimmung geometrischer und dynamischer Meßparameter - Video Capillary Microscopy: Determination of Geometrical and Dynamic ParametersBiomedizinische Technik/Biomedical Engineering, 1987
- Red blood cell velocity in nailfold capillaries of man measured by a television microscopy techniqueMicrovascular Research, 1974
- A Method for Studying the Dynamics of Transcapillary Transfer Quantitatively At the Microscopic Level in Situ in Living OrgansAngiology, 1963