The ParaSight-F rapid dipstick antigen capture assay for monitoring parasite clearance after drug treatment of Plasmodium falciparum malaria.
- 1 July 1997
- journal article
- Published by Oxford University Press (OUP) in Transactions of the Royal Society of Tropical Medicine and Hygiene
- Vol. 91 (4), 403-405
- https://doi.org/10.1016/s0035-9203(97)90257-1
Abstract
Three methods for the detection of Plasmodium falciparum infection in peripheral blood were compared during antimalarial treatment and follow-up in 32 Burundian patients: dipstick antigen capture assay, standard (TBF) and prolonged thick blood film examination (PTBF) (3×5 min and 3×20 min examination respectively). Parasitaemia was determined daily by comparison with total white blood cell counts (determined by Coulter counter) until no parasite was detected on 2 consecutive days by PTBF. Cumulatively, 231 observations were made with each assay: 64 were negative and 167 positive by PTBF (59 had parasite counts ≤100/μL). Compared to PTBF, the sensitivities of TBF and the dipstick assay were 1 · 0 for parasite counts >100/μL and 0 · 458 and 0 · 966 respectively for counts ≤100/μL. Overall, the dipstick assay was significantly more sensitive (0 · 988 vs. 0 · 808;P < 0 · 001) but less specific (P = 0 · 013) than TBF. The dipstick assay is of potential use for monitoring response to drug treatment and for detecting low parasitaemias.Keywords
This publication has 7 references indexed in Scilit:
- The ParaSightR-F test: A simple rapid manual dipstick test to detect Plasmodium falciparum infectionParasitology Today, 1994
- Diagnosis of malaria by detection of Plasmodium falciparum HRP-2 antigen with a rapid dipstick antigen-capture assayThe Lancet, 1994
- The rapid manual ParaSight®-F test. A new diagnostic tool for Plasmodium falciparum infectionTransactions of the Royal Society of Tropical Medicine and Hygiene, 1993
- Identification of the four human malaria parasite species in field samples by the polymerase chain reaction and detection of a high prevalence of mixed infectionsMolecular and Biochemical Parasitology, 1993
- Rapid diagnosis of malaria by fluorescence microscopy with light microscope and interference filterThe Lancet, 1991
- RAPID DIAGNOSIS OF MALARIA BY ACRIDINE ORANGE STAINING OF CENTRIFUGED PARASITESThe Lancet, 1989
- Rapid evaluation of malaria parasite density and standardization of thick smear examination for epidemiological investigationsTransactions of the Royal Society of Tropical Medicine and Hygiene, 1985