Three-Dimensional Representation of Complex Muscle Architectures and Geometries
Top Cited Papers
- 1 May 2005
- journal article
- research article
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 33 (5), 661-673
- https://doi.org/10.1007/s10439-005-1433-7
Abstract
Almost all computer models of the musculoskeletal system represent muscle geometry using a series of line segments. This simplification (i) limits the ability of models to accurately represent the paths of muscles with complex geometry and (ii) assumes that moment arms are equivalent for all fibers within a muscle (or muscle compartment). The goal of this work was to develop and evaluate a new method for creating three-dimensional (3D) finite-element models that represent complex muscle geometry and the variation in moment arms across fibers within a muscle. We created 3D models of the psoas, iliacus, gluteus maximus, and gluteus medius muscles from magnetic resonance (MR) images. Peak fiber moment arms varied substantially among fibers within each muscle (e.g., for the psoas the peak fiber hip flexion moment arms varied from 2 to 3 cm, and for the gluteus maximus the peak fiber hip extension moment arms varied from 1 to 7 cm). Moment arms from the literature were generally within the range of fiber moment arms predicted by the 3D models. The models accurately predicted changes in muscle surface geometry over a 55° range of hip flexion, as compared to changes in shape predicted from MR images (average errors between the model and measured surfaces were between 1.7 and 5.2 mm). This new framework for representing muscle will enhance the accuracy of computer models of the musculoskeletal system.Keywords
This publication has 46 references indexed in Scilit:
- A 3D model of muscle reveals the causes of nonuniform strains in the biceps brachiiJournal of Biomechanics, 2004
- Real‐time imaging of skeletal muscle velocityJournal of Magnetic Resonance Imaging, 2003
- Documentation and three‐dimensional modelling of human soleus muscle architectureClinical Anatomy, 2003
- Individual muscle contributions to support in normal walkingGait & Posture, 2003
- Cine Phase-Contrast Magnetic Resonance Imaging As a Tool for Quantification of Skeletal Muscle MotionSeminars in Musculoskeletal Radiology, 2003
- Dynamic Optimization of Human WalkingJournal of Biomechanical Engineering, 2001
- Accuracy of Muscle Moment Arms Estimated from MRI-Based Musculoskeletal Models of the Lower ExtremityComputer Aided Surgery, 2000
- A method for registration of 3-D shapesIEEE Transactions on Pattern Analysis and Machine Intelligence, 1992
- The Architecture of Leg MusclesPublished by Springer Nature ,1990
- Determination of Muscle Orientations and Moment ArmsJournal of Biomechanical Engineering, 1984