Osteogenesis at the dental implant interface: High‐voltage electron microscopic and conventional transmission electron microscopic observations
- 1 June 1993
- journal article
- research article
- Published by Wiley in Journal of Biomedical Materials Research
- Vol. 27 (6), 791-800
- https://doi.org/10.1002/jbm.820270612
Abstract
The osteogenesis of mandibular bone to endosteal dental implants was examined using an in vivo dog model. One half of the implants examined were unloaded implants, with the remaining one half prosthodontically loaded for 6 months. Undecalcified mandibular implant samples were examined with both high-voltage electron microscopy (HVEM) stereology and routine transmission electron microscopy. The osseous interface to integrated implants was shown to vary in its morphology. Mineralized bone was observed directly apposing the implant, often separated from the implant by an electron-dense deposit of approximately 50 nm. Within this densely mineralized matrix, osteocytes were routinely observed. Adjacent areas were shown to contain slightly wider zones of either a less dense mineralized matrix or, alternatively, unmineralized tissue. Other zones consisted of wider unmineralized matrices containing collagen fibers and osteoblasts. These latter zones were consistent with the appearance of an appositional type of bone growth. Because bone is a dynamic, actively remodeling tissue, a varied morphology of the support tissues to dental implant is not unexpected. Areas of mature bone interfacing with successfully integrated implants were demonstrated, as well as areas adjacent to the mature bone that were undergoing remodeling or mineralization. This study has also shown that HVEM stereology is a valuable research tool to investigate the oral tissue interface with dental implants. © 1993 John Wiley & Sons, Inc.Keywords
This publication has 17 references indexed in Scilit:
- Transmission Electron Microscopic and High Voltage Electron Microscopic Observations of the Bone and Osteocyte Activity Adjacent to Unloaded Dental Implants Placed in DogsThe Journal of Periodontology, 1992
- Light and Transmission Electron Microscopy of the Intact Interfaces Between Non-submerged Titanium-coated Epoxy Resin Implants and Bone or GingivaJournal of Dental Research, 1992
- Osseointegration of two types of implants in nonhuman primatesThe Journal of Prosthetic Dentistry, 1988
- A Histological Assessment of the Initial Healing Response Adjacent to Porous-surfaced, Titanium Alloy Dental Implants in DogsJournal of Dental Research, 1986
- Chemical Softening and Wear of Dental CompositesJournal of Dental Research, 1985
- Evidence for a Junctional Epithelial Attachment to Ceramic Dental ImplantsThe Journal of Periodontology, 1985
- Osseous adaptation to continuous loading of rigid endosseous implantsAmerican Journal of Orthodontics, 1984
- Electron Microscopic Analysis of the Bone-Titanium InterfaceActa Orthopaedica, 1983
- A 15-year study of osseointegrated implants in the treatment of the edentulous jawInternational Journal of Oral Surgery, 1981
- Osseointegrated Titanium Implants:Requirements for Ensuring a Long-Lasting, Direct Bone-to-Implant Anchorage in ManActa Orthopaedica, 1981