Detection of liver metastases with superparamagnetic iron oxide in 15 patients: results of MR imaging at 1.5 T

Abstract
The first clinical results of using superparamagnetic ferrite particles as a tissue-specific contrast agent for MR of the liver are reported at high fields (1.5 T). Fifteen patients with proved secondary liver malignancies were studied with plain and contrast-enhanced MR. Superparamagnetic iron oxide was administrated IV in a dose of 20 mumol/kg. Intermediate TR, 820/30, 60 (TR/TE), and long TR, 2200/22, 70, spin-echo sequences were used before and 1 hr after injection of contrast material. Before injection, the largest number of lesions (437) was detected with the T2-weighted sequence. Lesion-to-liver contrast, expressed as the difference between the tumor and liver signal-to-noise, improved after ferrite administration in both sequences from -1 to 20 and from 7 to 15 for the 820/30, 60 sequence and from 9 to 34 and 15 to 21 for the 2200/22, 70 sequence. Despite this significant improvement in terms of the number of lesions detected, contrast-enhanced images did not show significantly more metastases tha...