Abstract
The half-value period of uranium II has been measured and found to be 1·70 × 105 years. The discrepancy between the two most recently determined measurements of the decay constant has been accounted for by using both an electrolytic method combined with a valve amplifier, and an ionization method using a Lindemann electrometer.

This publication has 9 references indexed in Scilit: