Effects of myocardial ischemia on quantitative ultrasonic backscatter and identification of responsible determinants.
- 1 July 1981
- journal article
- research article
- Published by Wolters Kluwer Health in Circulation Research
- Vol. 49 (1), 89-96
- https://doi.org/10.1161/01.res.49.1.89
Abstract
Quantitative characterization of myocardial properties represent a rapidly emerging area of echocardiographic investigation. Because measurement of the ultrasonic integrated backscatter is theoretically applicable to analysis in vivo with reflected ultrasound, this study was performed to develop and evaluate a suitable method for measurement of quantitative backscatter in vivo. In view of the desirability of characterizing ischemic myocardium noninvasively, the study was performed with animal preparations simulating myocardial ischemia in humans. In one series of open-chest dogs, integrated backscatter among 22 ischemic regions was increased by 200% (P less than 0.01) compared to values in control regions within 1 hour after coronary occlusion and by 400% (-45.1 +/- 0.7 dB compared to -50.9 +/- 0.4 dB) (P less than 0.001) within 6 hours. In a second series of open-chest dogs, ischemia was quantified with 141Ce microspheres, and mean integrated backscatter was found to increase (280% of control) (P less than 0.01) in regions with flow less than 20% of control 2 hours following coronary occlusion. Additional studies with perfused hearts revealed two determinants of the increased ultrasonic backscatter observed: (1) an increase in cardiac fluid content reflected by the wet-to-dry weight ratio, and (2) the contributions of formed elements in whole blood. The results indicate that ultrasonic integrated backscatter distinguishes severely ischemic from nonischemic myocardium in vivo in open-chest animals. Because it was possible to obtain these results in the reflection mode, potential extension of the approach to clinical applications is promising.This publication has 8 references indexed in Scilit:
- Estimating the Acoustic Attenuation Coefficient Slope for Liver from Reflected Ultrasound SignalsIEEE Transactions on Sonics and Ultrasonics, 1979
- Blood flow measurements with radionuclide-labeled particlesProgress in Cardiovascular Diseases, 1977
- Detection of edema associated with myocardial ischemia by computerized tomography in isolated, arrested canine hearts.Circulation, 1977
- Scattering of Ultrasound by BloodIEEE Transactions on Biomedical Engineering, 1976
- Ultrasonic tissue characterizationPublished by National Institute of Standards and Technology (NIST) ,1976
- The “No-Reflow” Phenomenon after Temporary Coronary Occlusion in the DogJournal of Clinical Investigation, 1974
- Correlation of echographic visualizability of tissue with biological composition and physiological stateThe Journal of the Acoustical Society of America, 1973
- Analysis and measurement of ultrasound backscattering from an ensemble of scatterers excited by sine-wave burstsThe Journal of the Acoustical Society of America, 1973