Clinical Performance and Physical Properties of Twelve Amalgam Alloys
- 9 November 1978
- journal article
- research article
- Published by SAGE Publications in Journal of Dental Research
- Vol. 57 (11-12), 983-988
- https://doi.org/10.1177/00220345780570111501
Abstract
An assessment of the marginal failure rate of 1,041 restorations of twelve alloys was made at one year. In addition, physical property tests were conducted. A correlation was found between the clinical performance and creep (.79), flow (.62) and 24-hour compressive strength (.60).Keywords
This publication has 9 references indexed in Scilit:
- Clinical Assessment of the Marginal Breakdown of Conventional Alloys Adjacent to a Dispersion AlloyJournal of Dental Research, 1976
- Three-year clinical comparison of three amalgam alloy types emphasizing an appraisal of the evaluation methods usedThe Journal of the American Dental Association, 1976
- Some Effects on the Phases of Amalgam Induced by CorrosionJournal of Dental Research, 1974
- Marginal Fracture of Amalgam RestorationsJournal of Dental Research, 1973
- Absence of the γ2 Phase in Amalgams with High Copper ConcentrationsJournal of Dental Research, 1972
- The Strength of Corroded AmalgamActa Odontologica Scandinavica, 1972
- Clinical evaluation of corrosion resistance of conventional alloy, spherical-particle alloy, and dispersion-phase alloyThe Journal of Prosthetic Dentistry, 1971
- Strength of the Mercury-Tin Phase in Dental AmalgamJournal of Dental Research, 1967
- The Mechanism of Marginal Fracture of Amalgam FillingsActa Odontologica Scandinavica, 1965