Enzyme-linked immunosorbent assay (ELISA) using antibody class capture for the detection of antitoxoplasma IgM.
Open Access
- 1 August 1982
- journal article
- research article
- Published by BMJ in Journal of Clinical Pathology
- Vol. 35 (8), 892-896
- https://doi.org/10.1136/jcp.35.8.892
Abstract
Sera from 180 patients with suspected toxoplasmic lymphadenopathy were examined for antitoxoplasma IgM by an enzyme-linked immunosorbent assay (ELISA), using antibody class capture (ACCA). Of 82 positive ACCA results, 78 were confirmed by testing the IgM fractions of the sera, obtained by sucrose density gradient centrifugation (SDGC). The four positive results which could not be confirmed were all from patients with at least a year's history of lymphadenopathy. Sera from 10 patients with low Sabin Feldman dye test (DT) titers gave positive ACCA results and subsequent specimens from them showed a rise in antibody concentration, confirming the diagnosis of acute toxoplasmosis. The antitoxoplasma IgM immunofluorescent antibody test (IgM-IFA) on whole serum was relatively insensitive and gave false-positive results with sera containing rheumatoid factor (RF) and antinuclear factor (ANF). There were no false-positive ACCA results with such sera, probably because the conjugates were prepared from F(ab')2 fragments of antitoxoplasma serum. The ACCA proved to be sensitive, specific and easily automated enabling examination of large numbers of specimens.This publication has 12 references indexed in Scilit:
- FALSE-POSITIVE SEROLOGICAL TESTS IN HEART TRANSPLANT RECIPIENTSThe Lancet, 1981
- An Enzyme-Linked Immunosorbent Assay for Detection of IgM Antibodies to Toxoplasma gondii: Use for Diagnosis of Acute Acquired ToxoplasmosisThe Journal of Infectious Diseases, 1980
- SPECIFIC DETECTION OF IgM-ANTIBODIES BY ELISA, APPLIED IN HEPATITIS-AThe Lancet, 1978
- Evaluation of a simplified sucrose gradient method for the detection of rubella‐specific IgM in routine diagnostic practiceJournal of Medical Virology, 1978
- Rheumatoid factors as a cause for false positive IgM anti-toxoplasma fluorescent tests. A technique for specific results.1972
- False-positive anti-Toxoplasma fluorescent-antibody tests in patients with antinuclear antibodies.1971
- Single-sample diagnosis of recent rubella by fractionation of antibody on Sephadex G-200 columnJournal of Clinical Pathology, 1971
- Crystals of Fragment Fab′: Preparation from Pepsin Digests of Human IgG Myeloma ProteinsNature, 1969
- IGM ANTIBODIES IN ACUTE TOXOPLASMOSIS .2. PREVALENCE AND SIGNIFICANCE IN ACQUIRED CASES1968
- Dyes as Microchemical Indicators of a New Immunity Phenomenon Affecting a Protozoon Parasite (Toxoplasma)Science, 1948