Wide variability in the sensitivity of APTT reagents for monitoring of heparin dosage.
Open Access
- 1 January 1996
- journal article
- research article
- Published by BMJ in Journal of Clinical Pathology
- Vol. 49 (1), 10-14
- https://doi.org/10.1136/jcp.49.1.10
Abstract
AIM: To assess the sensitivity of activated partial thromboplastin time (APTT) reagents for monitoring heparin dosage using data from the UK National External Quality Assessment Scheme (NEQAS) for blood coagulation. METHODS: Data were reviewed from four surveys using samples prepared by addition of heparin to normal plasma in vitro and from two surveys in which samples were prepared using plasma from patients receiving heparin therapy (ex vivo samples). RESULTS: For both in vitro and ex vivo samples, notable differences between APTT reagents with respect to heparin sensitivity were noted. This indicates that a uniform therapeutic range of 1.5-2.5 calculated by the APTT ratio may not be appropriate for all reagents. Reagent sensitivity in ex vivo samples was substantially different to that in in vitro samples. CONCLUSIONS: The results of this large series of laboratories clearly indicate that reagent specific therapeutic ranges may be necessary, and that samples prepared by the addition of heparin to normal plasma in vitro can be misleading and should not be used.Keywords
This publication has 20 references indexed in Scilit:
- An attempt to standardize APTT reagents used to monitor heparin therapyBlood Coagulation & Fibrinolysis, 1992
- Heparin for 5 Days as Compared with 10 Days in the Initial Treatment of Proximal Venous ThrombosisNew England Journal of Medicine, 1990
- Comparison of High-Dose with Low-Dose Subcutaneous Heparin to Prevent Left Ventricular Mural Thrombosis in Patients with Acute Transmural Anterior Myocardial InfarctionNew England Journal of Medicine, 1989
- The Variations Between Heparin Sensitivity of Different Lots of Activated Partial Thromboplastin Time Reagent Produced by the Same ManufacturerAmerican Journal of Clinical Pathology, 1988
- Continuous Intravenous Heparin Compared with Intermittent Subcutaneous Heparin in the Initial Treatment of Proximal-Vein ThrombosisNew England Journal of Medicine, 1986
- Heparin Monitoring by Activated Partial Thromboplastin Time: Comparison of Ex Vivo Measurement and In Vitro Standardization.American Journal of Clinical Pathology, 1985
- Heparin and the Activated Partial Thromboplastin Time — A Difference between theIn-vitroandIn-vivoEffects and Implications for the Therapeutic RangeAmerican Journal of Clinical Pathology, 1980
- RELEVANCE OF PREOPERATIVE AND POSTOPERATIVE BLOOD TESTS TO POSTOPERATIVE LEG-VEIN THROMBOSISThe Lancet, 1973
- A Prospective Study of the Value of Monitoring Heparin Treatment with the Activated Partial Thromboplastin TimeNew England Journal of Medicine, 1972
- Gerinnungsphysiologische Schnellmethode zur Bestimmung des FibrinogensActa Haematologica, 1957