Determination of Glomerular Filtration Rate in Advanced Renal Insufficiency
- 1 January 1978
- journal article
- research article
- Published by Taylor & Francis in Scandinavian Journal of Urology and Nephrology
- Vol. 12 (2), 133-137
- https://doi.org/10.3109/00365597809179980
Abstract
The glomerular filtration rate (GFR) has been determined in 17 patients with advanced renal insufficiency (GFR less than 15 ml/min) by different clearance techniques using creatinine, inulin and 51Cr-EDTA as filtration markers. With renal inulin clearance as reference method for GFR, endogenous renal creatinine clearance overestimated GFR by an average of 30%. Renal clearance of 51Cr-EDTA and inulin were closely correlated and thus 51Cr-EDTA is a suitable GFR marker even at low filtration rates. However, it was found that the plasma clearance of 51Cr-EDTA overestimated the GFR often by more than 100% in the range 2.6--11.2 ml/min. Renal clearance measured during 24 h was lower than 4 h renal clearance with the patient well hydrated and resting in bed. It is concluded that the precise measurement of low glomerular filtration rates requires the use of renal clearance techniques. Four-hour 51Cr-EDTA renal clearance is a suitable method for measuring and following the development of renal function in advanced renal insufficiency.Keywords
This publication has 10 references indexed in Scilit:
- Comparison between Total and Renal Plasma Clearance of [51Cr]EDTAScandinavian Journal of Clinical and Laboratory Investigation, 1976
- A Simple Method for the Determination of Glomerular Filtration RateScandinavian Journal of Clinical and Laboratory Investigation, 1972
- Renal Hemodynamics and Limitations of Creatinine Clearance in Determining Filtration Rate in Glomerular DiseaseScandinavian Journal of Urology and Nephrology, 1971
- GLOMERULAR FILTRATION RATE IN PATIENTS WITH SEVERE AND VERY SEVERE RENAL INSUFFICIENCYActa Medica Scandinavica, 1970
- Renal Inulin Clearance versus Total Plasma Clearance of51Cr-EDTAScandinavian Journal of Clinical and Laboratory Investigation, 1969
- MEASUREMENT OF GLOMERULAR FILTRATION-RATE IN MAN USING A 51Cr/EDETIC-ACID COMPLEXThe Lancet, 1967
- Glomerular Filtration RatePublished by American Medical Association (AMA) ,1967
- Chromium-51 Ethylenediaminetetraacetate for Estimation of Glomerular Filtration RateScience, 1966
- The Relationship Between Endogenous Creatinine Clearance and Serum Creatinine in Renal FailureScandinavian Journal of Clinical and Laboratory Investigation, 1964
- THE DETERMINATION OF INULINPublished by Elsevier ,1942