Influence of Nonionic Surfactants on the Potentiometric Response of Hydrogen Ion-Selective Polymeric Membrane Electrodes
- 1 May 1996
- journal article
- research article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 68 (9), 1623-1631
- https://doi.org/10.1021/ac951017g
Abstract
The influence of poly(ethylene oxide)-based nonionic surfactants (i.e., Triton X-100 and Brij 35) in the sample phase on the response properties of hydrogen ion-selective polymeric membrane electrodes containing mobile (lipophilic amines) or covalently bound (aminated-poly(vinyl chloride)) hydrogen ion carriers is reported. In the presence of these nonionic surfactants, membrane electrode response toward interfering cation activity (e.g., Na+) in the sample phase is increased substantially and the pH measuring range shortened. The degree of cation interference for pH measurements is shown to correlate with the basicity of the hydrogen ion carrier doped within the membrane phase. The observed deterioration in selectivity arises from the partitioning of the surfactant into the membrane and concomitant extraction of metal cations by the surfactants in the organic phase. The effect of nonionic surfactants on pH electrodes prepared with aminated-PVC membranes is shown to be more complex, with additional large shifts in EMF values apparently arising from multidentate interactions between the surfactant molecules and the polymeric amine in the membrane, leading to a change in the apparent pKa values for the amine sites. The effects induced by nonionic surfactants on the EMF response function of hydrogen ion-selective polymeric membrane electrodes are modeled, and experimental results are shown to correlate well with theoretical predictions.Keywords
This publication has 21 references indexed in Scilit:
- Optimum composition of neutral carrier based pH electrodesAnalytica Chimica Acta, 1994
- Planar micro sensors for in vivo myocardial pH measurementsTalanta, 1994
- Simplified dual-lumen catheter design for simultaneous potentiometric monitoring of carbon dioxide and pHAnalytical Chemistry, 1994
- Electrochemical characterization of aminated PVC‐based ion‐selective membranesElectroanalysis, 1993
- Synthesis and characterization of neutral hydrogen ion-selective chromoionophores for use in bulk optodesAnalytica Chimica Acta, 1993
- New Whole Blood Analyzers and Their Impact on Cardiac and Critical CareCritical Reviews in Clinical Laboratory Sciences, 1993
- Complexation of Polymeric Acids with Polymeric BasesPublished by American Chemical Society (ACS) ,1992
- Liquid—liquid extraction of alkali metal ions with non-ionic surfactant having a poly(oxyethylene) chainAnalytica Chimica Acta, 1992
- A hydrogen ion-selective liquid-membrane electrode based on tri-n-dodecylamine as neutral carrierAnalytica Chimica Acta, 1981
- Barium ion-selective electrode based on a neutral carrier complexAnalytical Chemistry, 1971