Influence of Arterial Input Function on Hypoperfusion Volumes Measured With Perfusion-Weighted Imaging
Open Access
- 1 January 2004
- journal article
- research article
- Published by Wolters Kluwer Health in Stroke
- Vol. 35 (1), 94-98
- https://doi.org/10.1161/01.str.0000106136.15163.73
Abstract
Background and Purpose— The arterial input function (AIF) is critical in determining hemodynamic parameters quantitatively with bolus-tracking MRI. We studied the effect of varying the location of measurement of AIF on the volume of hypoperfusion. We compared the volumes of hypoperfusion obtained with different AIFs with the final ischemic lesion volume. Methods— We included 13 patients with acute cerebral ischemia in the anterior circulation who underwent diffusion- (DWI) and perfusion (PWI)-weighted imaging within 8 hours after symptom onset and exhibited DWI lesion expansion between baseline and follow-up. AIF was measured at 4 locations: near both middle cerebral arteries (MCAs), in MCA branches adjacent to the largest DWI abnormality, and at the same level on the opposite hemisphere. Hypoperfusion lesion volumes were compared with the DWI volume at follow-up. Results— Large variations in PWI lesion size were found with different AIF locations. The largest PWI lesions were found when AIF was measured at the contralateral MCA. Smaller PWI lesions were found when AIF was measured in the other locations. There was no significant difference between PWI lesion area at baseline and follow-up DWI lesion when AIF was measured at the contralateral MCA. The other PWI lesions significantly underestimated follow-up DWI lesion size. Conclusions— AIF is an important determinant of the size of hypoperfusion lesions measured with PWI. PWI lesion volumes determined with AIF from the contralateral MCA are associated with follow-up lesion volume.Keywords
This publication has 16 references indexed in Scilit:
- Quantification of Perfusion Using Bolus Tracking Magnetic Resonance Imaging in StrokeStroke, 2002
- Is quantification of bolus tracking MRI reliable without deconvolution?Magnetic Resonance in Medicine, 2001
- Evolution of Cerebral Infarct Volume Assessed by Diffusion-Weighted Magnetic Resonance ImagingArchives of Neurology, 2001
- Correcting partial volume artifacts of the arterial input function in quantitative cerebral perfusion MRIMagnetic Resonance in Medicine, 2001
- Delay and dispersion effects in dynamic susceptibility contrast MRI: Simulations using singular value decompositionMagnetic Resonance in Medicine, 2000
- Measuring Cerebral Blood Flow Using Magnetic Resonance Imaging TechniquesJournal of Cerebral Blood Flow & Metabolism, 1999
- Automated Image Registration: I. General Methods and Intrasubject, Intramodality ValidationJournal of Computer Assisted Tomography, 1998
- High resolution measurement of cerebral blood flow using intravascular tracer bolus passages. Part I: Mathematical approach and statistical analysisMagnetic Resonance in Medicine, 1996
- Classification of subtype of acute ischemic stroke. Definitions for use in a multicenter clinical trial. TOAST. Trial of Org 10172 in Acute Stroke Treatment.Stroke, 1993
- Cerebral Transit of an Intravascular Tracer May Allow Measurement of Regional Blood Volume but Not Regional Blood FlowJournal of Cerebral Blood Flow & Metabolism, 1984