In‐vivo validation of on‐line and off‐line geometric coronary measurements using insertion of stenosis phantoms in porcine coronary arteries
- 1 September 1992
- journal article
- research article
- Published by Wiley in Catheterization and Cardiovascular Diagnosis
- Vol. 27 (1), 16-27
- https://doi.org/10.1002/ccd.1810270106
Abstract
Geometric coronary artery measurements with the Phillips Digital Cardiac Imaging System (DCI) and the Cardiovascular Angiography Analysis System (CAAS) were validated using percutaneous insertion of radiolucent stenosis phantoms in swine coronary arteries. Angiographic visualization of the stenosis lumens (ϕ 0.5, 0.7, 1.0, 1.4, 1.9 mm) was simultaneously recorded on DCI and cinefilm. The acquisition systems were calibrated by either the diameter of the guiding catheter (catheter CAL) or the isocenter method (iso-center CAL). Minimal luminal diameters (MLD) obtained with CAAS and DCI on 20 corresponding cineframes were compared with the true phantom diameters (PD). The accuracy of MLD measurements with the CAAS using isocenter CAL was –0.07mm, the precision 0.21 mm (r=0.91; y = 0.30 + 0.79x; SEE = 0.19), with catheter CAL the accuracy was 0.09 mm, the precision 0.23 mm (r=0.89; y = 0.19 + 0.74x; SEE = 0.19). The accuracy of MLD measurements using the DCI with isocenter CAL was 0.08 mm, the precision 0.15 min (r = 0.96; y = 0.08 + 0.86x; SEE = 0.14), with catheter CAL the accuracy was 0.18 mm, the precision 0.21 mm (r=0.92; y = 0.09 + 0.76x; SEE = 0.17). DCI underestimated PD with isocenter CAL (p p < 0.001). MLD can be measured with high accuracy, both applying on-line digital as well as off-line cineangiographic analysis. The results of digital measurements demonstrate high reliability of the new digital software package.Keywords
This publication has 17 references indexed in Scilit:
- Pitfalls in the determination of absolute dimensions using angiographic catheters as calibration devices in quantitative angiographyThe American Journal of Cardiology, 1991
- Restenosis after coronary angioplasty: New standards for clinical studiesJournal of the American College of Cardiology, 1990
- Change in diameter of coronary artery segments adjacent to stenosis after percutaneous transluminal coronary angioplasty: Failure of percent diameter stenosis measurement to reflect morphologic changes induced by balloon dilationJournal of the American College of Cardiology, 1988
- A Comparison of 35 mm Cine Film and Digital Radiographic Image RecordingInvestigative Radiology, 1988
- Potential errors in the estimation of coronary arterial stenosis from clinical arteriography with reference to the shape of the coronary arterial lumen.Heart, 1986
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986
- Assessment of short-, medium-, and long-term variations in arterial dimensions from computer-assisted quantitation of coronary cineangiograms.Circulation, 1985
- Assessment of dimensions and image quality of coronary contrast catheters from cineangiogramsCatheterization and Cardiovascular Diagnosis, 1985
- Coronary angiographic examination with the dynamic spatial reconstructor.Circulation, 1984
- Quantification of relative coronary arterial stenosis by cinevideodensitometric analysis of coronary arteriograms.Circulation, 1984