Microfabricated Differential Mobility Spectrometry with Pyrolysis Gas Chromatography for Chemical Characterization of Bacteria
- 7 August 2004
- journal article
- research article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 76 (17), 5208-5217
- https://doi.org/10.1021/ac0497611
Abstract
A microfabricated drift tube for differential mobility spectrometry (DMS) was used with pyrolysis-gas chromatography (py-GC) to chemically characterize bacteria through three-dimensional plots of ion intensity, compensation voltage from differential mobility spectra, and chromatographic retention time. The DMS analyzer provided chemical information for positive and negative ions simultaneously from chemical reactions between pyrolysis products in the GC effluent and reactant ions of H+(H2O)n and O2-(H2O)n in air at ambient pressure. Authentic standards for chemicals formed in the pyrolysis of bacteria showed favorable matches with plots from py-GC/DMS analysis and were supported by py-GC/MS results. These and other yet-unidentified constituents provided a means to distinguish Escherichia coli from Micrococcus luteus. A Gram-positive spore former (Bacillus megaterium) was distinguished by an abundant peak for crotonic acid evident in positive and negative ions and not observed with M. luteus. In contrast, plots from py-GC/DMS of lipid A and lipoteichoic acid showed poor matches to plots for a Gram-negative (E. coli) bacterium and a Gram-positive (M. luteus) bacterium and the differences were attributed to differences in genus sources of the biopolymers. A significant percentage of the chemical information available in py-GC/DMS is unidentified, and the analytical utility must be established. Precision in the chemical measurement was determined as ±0.2 V, 10% relative standard deviation (RSD), and ±0.05 min for compensation voltage, peak intensity, and retention time, respectively. The minimum number of total bacteria (cell forming units) detected was 6000 though detection limits and resolution could be varied by the magnitude of the separation voltage in the differential mobility spectrometer.Keywords
This publication has 23 references indexed in Scilit:
- A MEMS radio-frequency ion mobility spectrometer for chemical vapor detectionSensors and Actuators A: Physical, 2001
- Comparison of high-field ion mobility obtained from drift tubes and a FAIMS apparatusInternational Journal of Mass Spectrometry, 2000
- A new method of separation of multi-atomic ions by mobility at atmospheric pressure using a high-frequency amplitude-asymmetric strong electric fieldInternational Journal of Mass Spectrometry and Ion Processes, 1993
- Recognition of chemical markers in chromatographic data by an individual feature approach to classification.Analytical Chemistry, 1992
- Characterization of underivatized lipid biomarkers from microorganisms with pyrolysis short-column gas chromatography/ion trap mass spectrometryAnalytical Chemistry, 1990
- Profiling, structural characterization, and trace detection of chemical markers for microorganisms by gas chromatography-mass spectrometryJournal of Microbiological Methods, 1989
- Carbohydrate profiling of bacteria by gas chromatography-mass spectrometry: Chemical derivatization and analytical pyrolysisEuropean Journal of Clinical Microbiology & Infectious Diseases, 1987
- Chemotaxonomy at a crossroads? : Gas chromatographic analyses of a single colony from the bacterium Haemophilus aphrophilusJournal of Chromatography B: Biomedical Sciences and Applications, 1986
- Classification of bacteria by pyrolysis-capillary column gas chromatography-mass spectrometry and pattern recognitionJournal of Analytical and Applied Pyrolysis, 1984
- Quantitative pyrolysis gas chromatography-mass spectrometry of bacterial cell wallsAnalytical Biochemistry, 1982