Oxygen saturation and breathing patterns in infancy. 1: Full term infants in the second month of life.
Open Access
- 1 May 1991
- journal article
- research article
- Published by BMJ in Archives of Disease in Childhood
- Vol. 66 (5), 569-573
- https://doi.org/10.1136/adc.66.5.569
Abstract
Overnight 12 hour tape recordings were made of arterial oxygen saturation (SaO2, pulse oximeter in the beat to beat mode) and abdominal wall breathing movement on 67 healthy, full term infants between the ages of 29 and 54 (median 39) days. The median baseline SaO2 during regular breathing was 99.8% (range 97.0-100%). Fifty four infants (81%) had shortlived episodes during which SaO2 fell to 80% or less (desaturation); the median rate was 0.9 desaturations/hour, and the median duration of each desaturation was 1.2 seconds. The 97th centile value for the duration of all episodes in which SaO2 fell to less than or equal to 80% was 4.0 seconds. The frequency of desaturations was significantly higher, and their duration significantly longer, when the breathing pattern was non-regular rather than regular. The percentage of apnoeic pauses (greater than or equal to 4 seconds in duration) followed by a desaturation was higher during non-regular than regular breathing; it was particularly high during periodic breathing. A knowledge of normal variability of baseline measurements of oxygenation and of the relationship between oxygenation and breathing patterns in infants is essential to the use of pulse oximetry in clinical practice.Keywords
This publication has 22 references indexed in Scilit:
- Recurrent cyanotic episodes with severe arterial hypoxaemia and intrapulmonary shunting: a mechanism for sudden death.Archives of Disease in Childhood, 1990
- Patterns of breathing during hypoxaemia in preterm infants at around term : C.F. Poets, V.A. Stebbens, M.P. Samuels and D.P. Southall, National Heart and Lung Institute, Brompton Hospital, London, U.K.Early Human Development, 1990
- Investigation of cyanotic/apneic episodes and sleep‐related upper airway obstruction by long‐term non‐invasive bedside recordingsPediatric Pulmonology, 1990
- Errors in 14 pulse oximeters during profound hypoxiaJournal of Clinical Monitoring and Computing, 1989
- Reliability of pulse oximetry in hypoxic infantsThe Journal of Pediatrics, 1988
- NONINVASIVE PULSE OXIMETRY IN CHILDREN WITH CYANOTIC CONGENITAL HEART DISEASECritical Care Medicine, 1987
- Pulse oximeter and transcutaneous arterial oxygen measurements in neonatal and paediatric intensive care.Archives of Disease in Childhood, 1987
- Respiratory Pauses and Periodic Breathing Assessed by Cardio-Pneumography in Normal Infants and in SIDS Siblings*Neuropediatrics, 1986
- Transcutaneous monitoring of oxygenation: What is normal?The Journal of Pediatrics, 1986
- Theophylline improves pneumogram abnormalities in infants at risk for sudden infant death syndromeThe Journal of Pediatrics, 1983