Comparison of the fast-neutron sensitivity of a Geiger-Muller counter using different techniques
- 1 January 1982
- journal article
- research article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 27 (1), 91-96
- https://doi.org/10.1088/0031-9155/27/1/009
Abstract
The sensitivity of an energy-compensated Geiger-Muller counter to neutrons with approximate energies of 0.6, 5 and 15 MeV, relative to its sensitivity to gamma rays (kU-value), has been determined at different centres in Europe. The time-of-flight, angular difference, associated-particle coincidence and lead filtration techniques have been compared, using the same Geiger-Muller counter. For 15 MeV neutrons, a consistent kU-value of 1.9% was obtained. For the lower neutron energies, lower kU values were observed with reasonable agreement.This publication has 5 references indexed in Scilit:
- UNCERTAINTIES IN THE MEASUREMENT OF AIRBORNE RADON DAUGHTERSHealth Physics, 1980
- The fast neutron sensitivity of a Geiger-Muller counter photon dosemeter by the time-of-flight techniquePhysics in Medicine & Biology, 1979
- Fast neutron sensitivities of Geiger-Mueller counter gamma dosemetersPhysics in Medicine & Biology, 1978
- Measurement of the Fast neutron sensitivities of Geiger-Mueller counter gamma dosemetersPhysics in Medicine & Biology, 1977
- A Geiger-Müeller γ-ray Dosimeter With Low Neutron SensitivityHealth Physics, 1961