Lipid-Coated Ultrastable Microbubbles as a Contrast Agent in Neurosonography
- 1 December 1990
- journal article
- research article
- Published by Wolters Kluwer Health in Investigative Radiology
- Vol. 25 (12), 1300-1304
- https://doi.org/10.1097/00004424-199012000-00005
Abstract
Simon RH, Ho S-Y, D'Arrigo J, Wakefield A, Hamilton SG. Liped-coated ultrastable microbubbles as a contrast agent in neurosonography. Invest Radiol 1990;25:1300–1304. Lipid-coated microbubbles can be synthesized from selected lpid monolayer systems for use as ultrasonic contrast. These microbubbles have the property of longevity of weeks in vitro (ultrastability) and longevity of hours in vivo. The bubbles can be manufactured with a mean diameter of approximately 2 μm in a tight diameter distribution; all are less than 6μm and 99% are smaller than 4.5 μm. The current study compared the in vivo survival characteristics of these lipid-coated microbubbles with microbubbles produced by saline. The comparison was made in the rat brain using direct intraparenchymal injections and injections into a previously created cyst/coagulum. The echogenic enhancement by the lipid-coated microbubbles persisted in vivo for over 24 hours in both the intraparenchymal environment and in the cyst/coagulum. The saline bubble echos were not detectable by 3 hours in a cyst/coagulum, and not detectable in the parenchyma after 2 hours. The sonographic characteristics and longevity of lipid-coated microbubbles make this agent a potentially useful clinical contrast material for neurosonography.This publication has 8 references indexed in Scilit:
- IV injection of air-filled human albumin microspheres to enhance arterial Doppler signal: a preliminary study in rabbitsAmerican Journal of Roentgenology, 1989
- Contrast agents in diagnostic ultrasoundJapanese Journal of Clinical Oncology, 1989
- Echocardiographic imaging of the left ventricle by peripheral intravenous injection of echo contrast agentAmerican Heart Journal, 1988
- Saline Microbubbles Monitoring Sonography-Assisted Abscess DrainageInvestigative Radiology, 1987
- Successful left ventricular opacification following peripheral venous injection of sonicated contrast agent: An experimental evaluationAmerican Heart Journal, 1987
- Physical factors influencing quantitation of two-dimensional contrast echo amplitudesJournal of the American College of Cardiology, 1984
- Hyperemic response of intracoronary contrast agents during two-dimensional echographic delineation of regional myocardiumJournal of the American College of Cardiology, 1984
- Correlation of myocardial echo contrast disappearance rate (“Washout”) and severity of experimental coronary stenosisJournal of the American College of Cardiology, 1984