Application of Virtual Surgical Planning with Computer Assisted Design and Manufacturing Technology to Cranio-Maxillofacial Surgery
Top Cited Papers
Open Access
- 1 July 2012
- journal article
- Published by Georg Thieme Verlag KG in Archives of Plastic Surgery
- Vol. 39 (04), 309-316
- https://doi.org/10.5999/aps.2012.39.4.309
Abstract
Computer aided design and manufacturing (CAD/CAM) technology today is the standard in manufacturing industry. The application of the CAD/CAM technology, together with the emerging 3D medical images based virtual surgical planning (VSP) technology, to craniomaxillofacial reconstruction has been gaining increasing attention to reconstructive surgeons. This article illustrates the components, system and clinical management of the VSP and CAD/CAM technology including: data acquisition, virtual surgical and treatment planning, individual implant design and fabrication, and outcome assessment. It focuses primarily on the technical aspects of the VSP and CAD/CAM system to improve the predictability of the planning and outcome.Keywords
This publication has 41 references indexed in Scilit:
- Accuracy and reliability of linear cephalometric measurements from cone-beam computed tomography scans of a dry human skullAmerican Journal of Orthodontics and Dentofacial Orthopedics, 2009
- Completing the 3-dimensional pictureAmerican Journal of Orthodontics and Dentofacial Orthopedics, 2008
- The value of stereolithographic models for preoperative diagnosis of craniofacial deformities and planning of surgical correctionsInternational Journal of Oral & Maxillofacial Surgery, 1998
- An integrated experimental approach to link a laser digitiser, a CAD/CAM system and a rapid prototyping system for biomedical applicationsThe International Journal of Advanced Manufacturing Technology, 1998
- Reconstruction of a Cranial Bone Defect With Hydroxyapatite and Free Flap TransferThe Journal of Craniofacial Surgery, 1997
- Pediatric craniofacial surgery: Comparison of milling and stereolithography for 3D model manufacturingPediatric Radiology, 1992
- Reproducibility of three-dimensional CT-assisted model production in the maxillofacial areaBritish Journal of Oral and Maxillofacial Surgery, 1992
- Computer-generated titanium cranioplasty: Report of a new technique for repairing skull defectsBritish Journal Of Neurosurgery, 1992
- Validation study of skull three‐dimensional computerized tomography measurementsAmerican Journal of Physical Anthropology, 1990
- Computer-Designed Prostheses for Orbitocranial ReconstructionPlastic and Reconstructive Surgery, 1988