Ultrahigh speed 1050nm swept source / Fourier domain OCT retinal and anterior segment imaging at 100,000 to 400,000 axial scans per second
Top Cited Papers
Open Access
- 3 September 2010
- journal article
- Published by Optica Publishing Group in Optics Express
- Vol. 18 (19), 20029-20048
- https://doi.org/10.1364/oe.18.020029
Abstract
We demonstrate ultrahigh speed swept source/Fourier domain ophthalmic OCT imaging using a short cavity swept laser at 100,000 – 400,000 axial scan rates. Several design configurations illustrate tradeoffs in imaging speed, sensitivity, axial resolution, and imaging depth. Variable rate A/D optical clocking is used to acquire linear-in-k OCT fringe data at 100kHz axial scan rate with 5.3um axial resolution in tissue. Fixed rate sampling at 1 GSPS achieves a 7.5mm imaging range in tissue with 6.0um axial resolution at 100kHz axial scan rate. A 200kHz axial scan rate with 5.3um axial resolution over 4mm imaging range is achieved by buffering the laser sweep. Dual spot OCT using two parallel interferometers achieves 400kHz axial scan rate, almost 2X faster than previous 1050nm ophthalmic results and 20X faster than current commercial instruments. Superior sensitivity roll-off performance is shown. Imaging is demonstrated in the human retina and anterior segment. Wide field 12×12mm data sets include the macula and optic nerve head. Small area, high density imaging shows individual cone photoreceptors. The 7.5mm imaging range configuration can show the cornea, iris, and anterior lens in a single image. These improvements in imaging speed and depth range provide important advantages for ophthalmic imaging. The ability to rapidly acquire 3D-OCT data over a wide field of view promises to simplify examination protocols. The ability to image fine structures can provide detailed information on focal pathologies. The large imaging range and improved image penetration at 1050nm wavelengths promises to improve performance for instrumentation which images both the retina and anterior eye. These advantages suggest that swept source OCT at 1050nm wavelengths will play an important role in future ophthalmic instrumentation.Keywords
This publication has 36 references indexed in Scilit:
- Generic real-time uniform K-space sampling method for high-speed swept-Source optical coherence tomographyOptics Express, 2010
- Limiting factors to the OCT axial resolution for in-vivo imaging of human and rodent retina in the 1060nm wavelength rangeOptics Express, 2009
- Ultra high-speed swept source OCT imaging of the anterior segment of human eye at 200 kHz with adjustable imaging rangeOptics Express, 2009
- Anterior segment imaging with Spectral OCT system using a high-speed CMOS cameraOptics Express, 2009
- Ultrahigh-Speed Optical Coherence Tomography for Three-Dimensional and En Face Imaging of the Retina and Optic Nerve HeadInvestigative Opthalmology & Visual Science, 2008
- In Vivo Three-Dimensional Imaging of Neovascular Age-Related Macular Degeneration Using Optical Frequency Domain Imaging at 1050 nmInvestigative Opthalmology & Visual Science, 2008
- Three-dimensional endomicroscopy using optical coherence tomographyNature Photonics, 2007
- Optical frequency domain imaging with a rapidly swept laser in the 815–870 nm rangeOptics Express, 2006
- In vivo optical frequency domain imaging of human retina and choroidOptics Express, 2006
- High-speed volumetric imaging of cone photoreceptors with adaptive optics spectral-domain optical coherence tomographyOptics Express, 2006