A sensitive pithed rat prepn. is described which can be used for testing small quantities of material for pressor assay. The anesthetized rat is pithed by forcing a rod through the eye and cranium and thence down the spinal canal. With proper adjustment of artificial respiration, very sensitive prepns. may be obtained which are suitable for testing 20 or 30 substances within a period of 5-7 hrs.