Rapid Prototyping of Microfluidic Systems in Poly(dimethylsiloxane)
- 24 October 1998
- journal article
- research article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 70 (23), 4974-4984
- https://doi.org/10.1021/ac980656z
Abstract
This paper describes a procedure that makes it possible to design and fabricate (including sealing) microfluidic systems in an elastomeric materialpoly(dimethylsiloxane) (PDMS)in less than 24 h. A network of microfluidic channels (with width >20 μm) is designed in a CAD program. This design is converted into a transparency by a high-resolution printer; this transparency is used as a mask in photolithography to create a master in positive relief photoresist. PDMS cast against the master yields a polymeric replica containing a network of channels. The surface of this replica, and that of a flat slab of PDMS, are oxidized in an oxygen plasma. These oxidized surfaces seal tightly and irreversibly when brought into conformal contact. Oxidized PDMS also seals irreversibly to other materials used in microfluidic systems, such as glass, silicon, silicon oxide, and oxidized polystyrene; a number of substrates for devices are, therefore, practical options. Oxidation of the PDMS has the additional advantage that it yields channels whose walls are negatively charged when in contact with neutral and basic aqueous solutions; these channels support electroosmotic pumping and can be filled easily with liquids with high surface energies (especially water). The performance of microfluidic systems prepared using this rapid prototyping technique has been evaluated by fabricating a miniaturized capillary electrophoresis system. Amino acids, charge ladders of positively and negatively charged proteins, and DNA fragments were separated in aqueous solutions with this system with resolution comparable to that obtained using fused silica capillaries.Keywords
This publication has 77 references indexed in Scilit:
- Protein Charge Ladders, Capillary Electrophoresis, and the Role of Electrostatics in Biomolecular RecognitionAccounts of Chemical Research, 1998
- Fabricating Large Arrays of Microwells with Arbitrary Dimensions and Filling Them Using Discontinuous DewettingAnalytical Chemistry, 1998
- Formation of Protein Charge Ladders by Acylation of Amino Groups on ProteinsJournal of the American Chemical Society, 1997
- Electrokinetic Focusing in Microfabricated Channel StructuresAnalytical Chemistry, 1997
- Design and development of a miniaturised total chemical analysis system for on-line lactate and glucose monitoring in biological samplesAnalytica Chimica Acta, 1997
- Generating Electrospray from Microchip Devices Using Electroosmotic PumpingAnalytical Chemistry, 1997
- Clinical potential of microchip capillary electrophoresis systemsElectrophoresis, 1997
- Integrated Microdevice for DNA Restriction Fragment AnalysisAnalytical Chemistry, 1996
- Behavior of microfluidic amplifiersSensors and Actuators A: Physical, 1996
- Microfluidics-a reviewJournal of Micromechanics and Microengineering, 1993