Automatic segmentation of echocardiographic sequences by active appearance motion models
Top Cited Papers
- 1 November 2002
- journal article
- clinical trial
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 21 (11), 1374-1383
- https://doi.org/10.1109/tmi.2002.806427
Abstract
A novel extension of active appearance models (AAMs) for automated border detection in echocardiographic image sequences is reported. The active appearance motion model (AAMM) technique allows fully automated robust and time-continuous delineation of left ventricular (LV) endocardial contours over the full heart cycle with good results. Nonlinear intensity normalization was developed and employed to accommodate ultrasound-specific intensity distributions. The method was trained and tested on 16-frame phase-normalized transthoracic four-chamber sequences of 129 unselected infarct patients, split randomly into a training set (n=65) and a test set (n=64). Borders were compared to expert drawn endocardial contours. On the test set, fully automated AAMM performed well in 97% of the cases (average distance between manual and automatic landmark points was 3.3 mm, comparable to human interobserver variabilities). The ultrasound-specific intensity normalization proved to be of great value for good results in echocardiograms. The AAMM was significantly more accurate than an equivalent set of two-dimensional AAMs.Keywords
This publication has 24 references indexed in Scilit:
- Application of point distribution models to the automated analysis of echocardiogramsPublished by Institute of Electrical and Electronics Engineers (IEEE) ,2002
- Statistical models of appearance for medical image analysis and computer visionPublished by SPIE-Intl Soc Optical Eng ,2001
- LV volume quantification via spatiotemporal analysis of real-time 3-D echocardiographyIEEE Transactions on Medical Imaging, 2001
- Active appearance modelsPublished by Institute of Electrical and Electronics Engineers (IEEE) ,2001
- Multistage hybrid active appearance model matching: segmentation of left and right ventricles in cardiac MR imagesIEEE Transactions on Medical Imaging, 2001
- Evaluating a robust contour tracker on echocardiographic sequencesMedical Image Analysis, 1999
- Autonomous Epicardial and Endocardial Boundary Detection in Echocardiographic Short-Axis ImagesJournal of the American Society of Echocardiography, 1998
- Echocardiographic estimation of left ventricular cavity area with a newly developed automated contour tracking method.Journal of the American Society of Echocardiography, 1997
- A multiple active contour model for cardiac boundary detection on echocardiographic sequencesIEEE Transactions on Medical Imaging, 1996
- Use of active shape models for locating structures in medical imagesImage and Vision Computing, 1994