To date, application of laser angioplasty in acute myocardial infarction (MI) has not been reported. In nine patients with acute myocardial infarction complicated by continuous or recurrent severe ischemia and chest pain, a mid‐infrared, solid‐state, pulse‐wave holmium/thulium:YAG coronary laser was applied. In six of these patients the laser was specifically utilized for the purpose of coronary thrombolysis. In each case a guidewire was placed across the stenosis and a multifiber laser catheter was utilized, emitting 250–600 mJ/pulse at 5 Hz, followed by adjunctive balloon angioplasty. Laser success (defined as ability to cross the lesion, reduction of ±20% in stenosis and thrombolysis when a thrombus is present) was achieved in all patients. Final angiograms revealed residual stenosis ±30%, adequate thrombolysis and no major complication (MI, perforation, emergency CABGS, CVA, death) in each patient. Clinically, all nine patients improved, survived the acute infarction and were discharged. This initial clinical experience demonstrates the feasibility and safety of holmium/thulium:YAG laser application in thrombolysis and plaque ablation in selected patients who experience acute myocardial infarction complicated by prolonged or recurrent ischemia and chest pain.Keywords
This publication has 15 references indexed in Scilit:
- Intracoronary urokinase as an adjunct to percutaneous transluminal coronary angioplasty in patients with complex coronary narrowings or angioplasty-induced complicationsThe American Journal of Cardiology, 1992
- Excimer laser-facilitated balloon angioplasty of a nondilatable lesionJournal of the American College of Cardiology, 1991
- National Heart, Lung, and Blood Institute Percutaneous Transluminal Coronary Angioplasty Registry as a standard for comparison of new devices. When should we use it, and what should we compare?Circulation, 1991
- Percutaneous coronary mid-infra-red laser angioplastyAmerican Heart Journal, 1991
- Holmium laser angioplasty after failed coronary balloon dilation: Use of a new solid‐state, infrared laser systemCatheterization and Cardiovascular Diagnosis, 1991
- Holmium laser angioplasty in coronary arteriesJournal of the American College of Cardiology, 1991
- Percutaneous coronary excimer laser-assisted balloon angioplasty: Initial clinical and quantitative angiographic results in 50 patientsJournal of the American College of Cardiology, 1991
- Intracoronary urokinase for intracoronary thrombus accumulation complicating percutaneous transluminal coronary angioplasty in acute ischemic syndromes.Circulation, 1990
- Percutaneous coronary excimer laser angioplasty in patients with stable and unstable angina pectoris. Acute results and incidence of restenosis during 6-month follow-up.Circulation, 1990
- Laser ablation of human atherosclerotic plaque without adjacent tissue injuryJournal of the American College of Cardiology, 1985