Comparison of measurements of neuroretinal rim area between confocal laser scanning tomography and planimetry of photographs
Open Access
- 1 April 1998
- journal article
- research article
- Published by BMJ in British Journal of Ophthalmology
- Vol. 82 (4), 362-366
- https://doi.org/10.1136/bjo.82.4.362
Abstract
BACKGROUND To compare neuroretinal rim area measurements by confocal scanning laser tomography and planimetric evaluation of optic disc photographs. METHODS For 221 patients with primary and secondary open angle glaucoma, 72 subjects with ocular hypertension, and 139 normal subjects, the optic disc was morphometrically analysed by the confocal scanning laser tomograph HRT (Heidelberg retina tomograph) and by planimetric evaluation of stereo colour optic disc photographs. RESULTS Absolute rim area and rim to disc area were significantly (pR 2=0.60 for rim to disc area andR 2=0.33 for absolute rim area. Planimetric measurements of rim area correlated significantly (pCONCLUSIONS Measurements of absolute rim area and rim to disc area are significantly larger with the HRT compared with planimetry of disc photographs. Differences between both methods depend on disc area, cup size and glaucoma stage. The reason may be that the HRT measures the retinal vessel trunk as part of the neuroretinal rim. The differences between both methods, which should be taken into account if disc measurements performed by both methods are compared with each other, may not influence the main advantage of the HRT—that is, morphological follow up examination of patients with glaucoma.Keywords
This publication has 24 references indexed in Scilit:
- Sources of Variability of Topometric Data With a Scanning Laser OphthalmoscopeArchives of Ophthalmology (1950), 1996
- Correlation of Visual Field With Scanning Confocal Laser Optic Disc Measurements in GlaucomaArchives of Ophthalmology (1950), 1995
- Optic nerve head analyser and Heidelberg retina tomograph: accuracy and reproducibility of topographic measurements in a model eye and in volunteers.British Journal of Ophthalmology, 1994
- Laser scanning tomography and stereophotogrammetry in three-dimensional optic disc analysisAlbrecht von Graefes Archiv für Ophthalmologie, 1993
- Optic Disc Size in Exfoliative, Primary Open Angle, and Low-Tension GlaucomaArchives of Ophthalmology (1950), 1992
- Racial Differences in Optic Nerve Head ParametersArchives of Ophthalmology (1950), 1989
- Optic Disc Rim Area Is Related to Disc Size in Normal SubjectsArchives of Ophthalmology (1950), 1987
- Neuroretinal Rim Area and Retinal Nerve Fiber Layer in GlaucomaArchives of Ophthalmology (1950), 1985
- Zur Bestimmung der wahren Größe eines Objektes auf dem Hintergrund des lebenden AugesKlinische Monatsblätter für Augenheilkunde, 1982
- THE VARIATION AND COVARIATION OF CUP AND DISC DIAMETERSActa Ophthalmologica, 1976