MIRACLE: mass isotopomer ratio analysis of U‐13C‐labeled extracts. A new method for accurate quantification of changes in concentrations of intracellular metabolites
- 20 January 2004
- journal article
- research article
- Published by Wiley in Biotechnology & Bioengineering
- Vol. 85 (6), 620-628
- https://doi.org/10.1002/bit.10907
Abstract
First, we report the application of stable isotope dilution theory in metabolome characterization of aerobic glucose limited chemostat culture of S. cerevisiae CEN.PK 113‐7D using liquid chromatography‐electrospray ionization MS/MS (LC‐ESI‐MS/MS). A glucose‐limited chemostat culture of S. cerevisiae was grown to steady state at a specific growth rate (μ) = 0.05 h−1 in a medium containing only naturally labeled (99% U‐12C, 1% U‐13C) carbon source. Upon reaching steady state, defined as 5 volume changes, the culture medium was switched to chemically identical medium except that the carbon source was replaced with 100% uniformly (U) 13C labeled stable carbon isotope, fed for 4 h, with sampling every hour. We observed that within a period of 1 h ∼80% of the measured glycolytic metabolites were U‐13C‐labeled. Surprisingly, during the next 3 h no significant increase of the U‐13C‐labeled metabolites occurred. Second, we demonstrate for the first time the LC‐ESI‐MS/MS‐based quantification of intracellular metabolite concentrations using U‐13C‐labeled metabolite extracts from chemostat cultivated S. cerevisiae cells, harvested after 4 h of feeding with 100% U‐13C‐labeled medium, as internal standard. This method is hereby termed “Mass Isotopomer Ratio Analysis of U‐13C Labeled Extracts” (MIRACLE). With this method each metabolite concentration is quantified relative to the concentration of its U‐13C‐labeled equivalent, thereby eliminating drawbacks of LC‐ESI‐MS/MS analysis such as nonlinear response and matrix effects and thus leads to a significant reduction of experimental error and work load (i.e., no spiking and standard additions). By coextracting a known amount of U‐13C labeled cells with the unlabeled samples, metabolite losses occurring during the sample extraction procedure are corrected for.Keywords
This publication has 28 references indexed in Scilit:
- Trehalose and glycogen accumulation is related to the duration of the G1phase ofSaccharomyces cerevisiaeFEMS Yeast Research, 2003
- Application of co‐eluting structural analog internal standards for expanded linear dynamic range in liquid chromatography/electrospray mass spectrometryRapid Communications in Mass Spectrometry, 2002
- New bioreactor‐coupled rapid stopped‐flow sampling technique for measurements of metabolite dynamics on a subsecond time scaleBiotechnology & Bioengineering, 2002
- Analysis of glycolytic intermediates in Saccharomyces cerevisiae using anion exchange chromatography and electrospray ionization with tandem mass spectrometric detectionAnalytica Chimica Acta, 2002
- Pulse Experiments as a Prerequisite for the Quantification of in Vivo Enzyme Kinetics in Aromatic Amino Acid Pathway of Escherichia coliBiotechnology Progress, 2002
- Advances in Proteome Analysis by Mass SpectrometryJournal of Biological Chemistry, 2001
- Integrated Genomic and Proteomic Analyses of a Systematically Perturbed Metabolic NetworkScience, 2001
- Sampling techniques and comparative extraction procedures for quantitative determination of intra- and extracellular metabolites in filamentous fungiFEMS Microbiology Letters, 1998
- Determination of intermediary metabolites in Aspergillus nigerJournal of Microbiological Methods, 1996
- Applications of isotope dilution-mass spectrometry in clinical chemistry, pharmacokinetics, and toxicologyMass Spectrometry Reviews, 1992