Abstract
The magnetic breakdown field Hp is calculated which, if applied at the surface of a super‐conductor, produces a critical power dissipation leading to a steep rise in the power loss. Generally Hp′ < Hc , the critical field of the material. The functional dependence of the Q of a microwave cavity for values of Hp near Hp is also found.