Design of short Spanish sentences for measuring reading performance: Radner-Vissum test
- 1 April 2008
- journal article
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 34 (4), 638-642
- https://doi.org/10.1016/j.jcrs.2007.11.046
Abstract
PURPOSE: To develop 24 short Spanish optotype sentences for the construction of a test based on the Radner reading test to simultaneously measure near visual acuity and reading speed. SETTING: Department of Refractive Surgery, Vissum-Instituto de Oftalmológico de Alicante, Alicante, Spain. METHODS: Thirty-one sentences were constructed in Spanish following the procedure defined by Radner to obtain sentence optotypes with comparable structure and the same lexical and grammatical difficulty. Sentences were statistically selected and standardized in 60 patients divided into 2 groups by educational level. Group A (30 patients) had a university education and Group B (30 patients), a primary school education. The interval of reading time was defined as the overall mean ±1.1 × SD. All sentences with a mean between 3.59 seconds and 4.04 seconds were selected for the reading charts. RESULTS: The mean age was 30.8 years ± 6.2 (SD) in Group A and 37.3 ± 10.7 years in Group B. The mean reading time was 3.8 ± 0.9 seconds in all patients, 3.5 ± 0.6 seconds in Group A, and 4.1 ± 1.0 seconds in Group B. CONCLUSION: The 24 short single Spanish sentences were highly comparable in syntactical structure; number, position, and length of words; lexical difficulty; and reading length.Keywords
This publication has 9 references indexed in Scilit:
- Discriminative power of reading tests to differentiate visual impairment caused by cataract and age-related macular degenerationJournal of Cataract & Refractive Surgery, 2005
- Reading performance depending on the type of cataract and its predictability on the visual outcomeJournal of Cataract & Refractive Surgery, 2004
- Reading performance with a refractive multifocal and a diffractive bifocal intraocular lensJournal of Cataract & Refractive Surgery, 2002
- The validity and reliability of short German sentences for measuring reading speedAlbrecht von Graefes Archiv für Ophthalmologie, 2002
- The effects of simulated cataract on reading with normal vision and simulated central scotomaVision Research, 1999
- Effect of a cataract simulation on clinical and real world vision.British Journal of Ophthalmology, 1996
- Printed cards for measuring low-vision reading speedVision Research, 1995
- Psychophysics of Reading. VIII. The Minnesota Low- Vision Reading TestOptometry and Vision Science, 1989
- THE DESIGN AND USE OF A NEW NEAR-VISION CHARTOptometry and Vision Science, 1980