Spiral CT Angiography Versus Aortography in the Assessment of Aortoiliac Length in Patients Undergoing Endovascular Abdominal Aortic Aneurysm Repair
- 1 August 1998
- journal article
- research article
- Published by International Society of Endovascular Specialists in Journal of Endovascular Surgery
- Vol. 5 (3), 222-227
- https://doi.org/10.1583/1074-6218(1998)005<0222:scavai>2.0.co;2
Abstract
To compare measurements of aortoiliac length obtained with spiral computed tomographic angiography (CTA) and aortography in patients undergoing endovascular aneurysm repair. The distances from the lower-most renal artery to the aortic bifurcation and from the aortic bifurcation to the common iliac artery (CIA) bifurcation were measured using both CTA and aortography in 108 patients with abdominal aortic aneurysms. The level of agreement between CTA and aortography was high, with 69% of aortic and 76% of iliac measurements within 1 cm and > 90% within 2 cm of each other. Mean differences were -0.35 +/- 1.20 cm and 0.25 +/- 1.10 cm, respectively, for aortic and iliac lengths. Aortography overestimated renal artery to aortic bifurcation length in comparison to CTA (p = 0.003), particularly in patients with large aneurysms (> 6.5 cm) and lumen diameters > 4.5 cm (p < 0.0001). Measurements of CIA length were shorter by aortography than CTA (p = 0.02). There is a high level of agreement between CTA and aortography in the measurement of aortoiliac length, but aortography overestimates renal artery to aortic bifurcation length in patients with large-diameter aneurysms and wide aneurysm lumens. CTA is sufficiently accurate in the majority of cases to be used as the sole basis for the construction of endovascular grafts.Keywords
This publication has 18 references indexed in Scilit:
- Imaging Modalities for Aortic EndograftingJournal of Endovascular Surgery, 1997
- Anatomical suitability of abdominal aortic aneurysms for endovascular repairBritish Journal of Surgery, 1997
- Comparison of magnetic resonance imaging measurements of abdominal aortic aneurysms with measurements obtained by other imaging techniques and intraoperative measurements: Possible implications for endovascular graftingJournal of Vascular Surgery, 1996
- Spiral CT Angiography for Preoperative Planning in Patients with Epigastric Tumors: Comparison with ArteriographyJournal of Computer Assisted Tomography, 1996
- Assessment of feasibility for endovascular prosthetic tube correction of aortic aneurysmBritish Journal of Surgery, 1995
- Spiral CT-angiography of the aortaEuropean Journal of Vascular Surgery, 1994
- Abdominal Aortic Aneurysm MeasurementInvestigative Radiology, 1992
- Preoperative evaluation of abdominal aortic aneurysms by computed tomographyAmerican Journal of Roentgenology, 1986
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986
- The value of arteriography before abdominal aneurysmectomyThe American Journal of Surgery, 1977