A tandem quadrupole/time-of-flight mass spectrometer with a matrix-assisted laser desorption/ionization source: design and performance
Top Cited Papers
- 9 June 2000
- journal article
- research article
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 14 (12), 1047-1057
- https://doi.org/10.1002/1097-0231(20000630)14:12<1047::aid-rcm990>3.0.co;2-e
Abstract
A matrix‐assisted laser desorption/ionization (MALDI) source has been coupled to a tandem quadrupole/time‐of‐flight (QqTOF) mass spectrometer by means of a collisional damping interface. Mass resolving power of about 10,000 (FWHM) and accuracy in the range of 10 ppm are observed in both single‐MS mode and MS/MS mode. Sub‐femtomole sensitivity is obtained in single‐MS mode, and a few femtomoles in MS/MS mode. Both peptide mass mapping and collision‐induced dissociation (CID) analysis of tryptic peptides can be performed from the same MALDI target. Rapid spectral acquisition (a few seconds per spectrum) can be achieved in both modes, so high throughput protein identification is possible. Some information about fragmentation patterns was obtained from a study of the CID spectra of singly charged peptides from a tryptic digest of E. coli citrate synthase. Reasonably successful automatic sequence prediction (>90%) is possible from the CID spectra of singly charged peptides using the SCIEX Predict Sequence routine. Ion production at pressures near 1 Torr (rather than in vacuum) is found to give reduced metastable fragmentation, particularly for higher mass molecular ions. © 2000 John Wiley & Sons, Ltd.Keywords
This publication has 30 references indexed in Scilit:
- The Characteristics of Peptide Collision-Induced Dissociation Using a High-Performance MALDI-TOF/TOF Tandem Mass SpectrometerAnalytical Chemistry, 1999
- Role of Accurate Mass Measurement (±10 ppm) in Protein Identification Strategies Employing MS or MS/MS and Database SearchingAnalytical Chemistry, 1999
- Peptide and protein identification by matrix-assisted laser desorption ionization (MALDI) and MALDI-post-source decay time-of-flight mass spectrometryJournal of the American Society for Mass Spectrometry, 1999
- Post-source decay analysis in matrix-assisted laser desorption/ionization mass spectrometry of biomoleculesJournal of Mass Spectrometry, 1997
- Mass Resolution Improvement by Incorporation of Pulsed Ion Extraction in a Matrix-Assisted Laser Desorption/Ionization Linear Time-of-Flight Mass SpectrometerAnalytical Chemistry, 1995
- Delayed extraction matrix‐assisted laser desorption time‐of‐flight mass spectrometryRapid Communications in Mass Spectrometry, 1995
- Improving the resolution of matrix-assisted laser desorption/ionization time-of-flight mass spectrometry by exploiting the correlation between ion position and velocityRapid Communications in Mass Spectrometry, 1994
- Peptide sequencing by matrix‐assisted laser‐desorption mass spectrometryRapid Communications in Mass Spectrometry, 1992
- Electrospray Ionization for Mass Spectrometry of Large BiomoleculesScience, 1989
- Laser desorption ionization of proteins with molecular masses exceeding 10,000 daltonsAnalytical Chemistry, 1988