The permeability of the corneal endothelium to fluorescein in the normal human eye
- 1 January 1984
- journal article
- research article
- Published by Taylor & Francis in Current Eye Research
- Vol. 3 (3), 509-513
- https://doi.org/10.3109/02713688408997239
Abstract
Endothelial permeability to fluorescein was measured as part of fluorophotometric studies of aqueous humor flow in 112 normal subjects whose ages span 6 decades. The permeability was 2.4 .+-. 0.9 .times. 10-4 cm/min (mean .+-. SD). Females had a slightly higher permeability than males. No correlation between age and permeability was noted. The precision of this method of measurement was .+-. 22%.This publication has 4 references indexed in Scilit:
- The Effect of Age on Aqueous Humor Formation in ManOphthalmology, 1981
- METHOD OF MEASURING AQUEOUS-HUMOR FLOW AND CORNEAL ENDOTHELIAL PERMEABILITY USING A FLUOROPHOTOMETRY NOMOGRAM1979
- A fluorophotometric study of the effect of topical timolol on aqueous humor dynamicsExperimental Eye Research, 1978
- A simple photographic method of measuring the volume of the anterior chamberExperimental Eye Research, 1963