Properties of Thrombin and Fibrinogen

Abstract
A standard clotting system has been analysed according to the average clotting time and variations due to thrombin, fibrinogen, day-to-day preparation of reagents and the clotting assay itself. The variations, εT, εF and ετ are reproducible and normally distributed with zero mean. Transfer of thrombin into a vessel produces adsorption losses at the solution-air (S/A) and solution-wall (S/W) interfaces. Specific loss at τ = 30 sec = (% loss in τ) (thrombin volume)/surface area. For clean non-polar surfaces such as polyethylene or paraffin the average S/W loss of 3.8%-cm (0.77 mg/m2) has the large coefficient of variation of 3.2%. Vessel surfaces may be saturated by prior conditioning using a thrombin concentration tenfold that required to give τ = 50 sec. Emptying and immediately refilling now gives an S/W loss of 0.19%-cm (0.04 mg/m2). The specific S/A loss, always present, is 2.7%-cm (0.54 mg/m2). The combined average loss for conditioned vessels is 1.0% at τ = 30 sec and is reproducible within sτ 2 for single vessels. A set of vessels gives a coefficient of variation of 0.53%. Stock fibrinogen aliquots are stored frozen at —95° and are thawed and diluted under standard conditions. If a syringe is used to withdraw clotting tube aliquots, SF2 is significantly increased over that obtained by using pipettes. Since pipettes do not contribute, the observed coefficient of variation of 1.7% then applies to the variation between tubes of stock-F. Six different lots of Fraction I gave a coefficient of variation of 12% between lot numbers. Experiments revealed a variance between equivalent experiments performed on different days (coefficient of variation 1.9%). Within this variance pairs of stock reagents were stable within the maximum limits of ± 0.12% of τ per day. There is no reason to suspect that either stock reagent has an intrinsic instability. The day-to-day variance given above arises from non-reproducibilities in the preparation of buffer diluents. Variances were reduced when buffers were prepared in deaerated water at room temperature. The total day-to-day coefficient of variation of fibrinogen of 1.5% and the variation between fibrinogen lots effectively eliminates this reagent as a reference standard. Thrombin appeared otherwise : by selecting and reusing reservoirs the maximum total thrombin day-to-day coefficient of variance is 0.36%. Thus, 95% of the thrombin concentrations prepared on different days will lie within 0.72% of the true value. By making use of known purification procedures it is possible to reproduce a stock thrombin reagent. This would serve as a universal standard.
Funding Information
  • National Science Foundation and the Institute of General Medical Sciences of the National Institutes of Health

This publication has 1 reference indexed in Scilit: