A Technique for Automated Quantification of Canine Glucocorticoid‐Induced Isoenzyme of Alkaline Phosphatase

Abstract
Summary: A sensitive assay for the corticosteroid‐induced alkaline phosphatase isoenzyme (CAP), adaptable to most clinical chemistry autoanalyzers, is described and validated. This assay is based on the greater than 98% inhibition of liver alkaline phosphatase isoenzyme (LAP) activity with 4.2 mM levamisole, as compared to the 42% inhibition of CAP activity. Analysis of serum with total alkaline phosphatase (AP) activity within the reference range, resulted in a reference range of 0 to 19 U/L for CAP activity. Analysis of serum from 160 clinical patients with AP activity above the reference range, revealed 73% with increased CAP activity ranging from 20 to 7,000 U/L. The diagnostic significance of this increased CAP activity is discussed.