High‐throughput screening of chemical exchange saturation transfer MR contrast agents
Open Access
- 1 May 2010
- journal article
- research article
- Published by Wiley in Contrast Media & Molecular Imaging
- Vol. 5 (3), 162-170
- https://doi.org/10.1002/cmmi.383
Abstract
A new high‐throughput MRI method for screening chemical exchange saturation transfer (CEST) agents is demonstrated, allowing simultaneous testing of multiple samples with minimal attention to sample configuration and shimming of the main magnetic field (B0). This approach, which is applicable to diamagnetic, paramagnetic and liposome CEST agents, employs a set of inexpensive glass or plastic capillary tubes containing CEST agents put together in a cheap plastic tube holder, without the need for liquid between the tubes to reduce magnetic susceptibility effects. In this setup, a reference image of direct water saturation spectra is acquired in order to map the absolute water frequency for each volume element (voxel) in the sample image, followed by an image of saturation transfer spectra to determine the CEST properties. Even though the field over the total sample is very inhomogeneous due to air–tube interfaces, the shape of the direct saturation spectra is not affected, allowing removal of susceptibility shift effects from the CEST data by using the absolute water frequencies from the reference map. As a result, quantitative information such as the mean CEST intensity for each sample can be extracted for multiple CEST agents at once. As an initial application, we demonstrate rapid screening of a library of 16 polypeptides for their CEST properties, but in principle the number of tubes is limited only by the available signal‐noise‐ratio, field of view and gradient strength for imaging. Copyright © 2010 John Wiley & Sons, Ltd.Keywords
This publication has 124 references indexed in Scilit:
- Feedback of mechanical effectiveness induces adaptations in motor modules during cyclingFrontiers in Computational Neuroscience, 2013
- How to assess performance in cycling: the multivariate nature of influencing factors and related indicatorsFrontiers in Physiology, 2013
- The relationship between cadence, pedalling technique and gross efficiency in cyclingEuropean Journal of Applied Physiology, 2011
- Water saturation shift referencing (WASSR) for chemical exchange saturation transfer (CEST) experimentsMagnetic Resonance in Medicine, 2009
- A PARACEST Agent Responsive to Inner- And Outer-Sphere Phosphate Ester Interactions for MRI ApplicationsJournal of the American Chemical Society, 2009
- Feasibility of concurrent dual contrast enhancement using CEST contrast agents and superparamagnetic iron oxide particlesMagnetic Resonance in Medicine, 2009
- New “multicolor” polypeptide diamagnetic chemical exchange saturation transfer (DIACEST) contrast agents for MRIMagnetic Resonance in Medicine, 2008
- Changes in muscle and joint coordination in learning to direct forcesHuman Movement Science, 2008
- Chemical Exchange Saturation Transfer Contrast Agents for Magnetic Resonance ImagingAnnual Review of Biomedical Engineering, 2008
- Assessment of glycosaminoglycan concentration in vivo by chemical exchange-dependent saturation transfer (gagCEST)Proceedings of the National Academy of Sciences, 2008