Objective. The aim of this study was to evaluate the accuracy and clinical usefulness of a new computer-driven, hand-held device (Chromatics Colormate III) to estimate serum bilirubin from skin-reflectance (skin color) of neonates. Study Design. A total of 2441 infants (both term and premature) at two hospitals had repeated measurements of transcutaneous bilirubin. Of these infants, 900 had one or more laboratory determinations of serum bilirubin. Many of the infants had early measurements of skin color before the onset of jaundice. A visual estimate of the degree of jaundice was made by a health care worker when the laboratory study was drawn. A subgroup of 61 infants was also studied while undergoing phototherapy with a total of 284 comparisons obtained. The reproducibility of the instrument was assessed separately using standardized color tiles and repeated measurements by multiple operators. Results. The range of serum bilirubin measurements that had concurrent skin color measurements was 3.22 to 338.1 μmol/L (0.2 to 21 mg/dL). The linear regression indicated an r = 0.956, and 95% of the skin color measurements were within 32.2 μmol/L (2.0 mg/dL). There was no interference with the accuracy of the device because of infant race or weight, or because of the use of phototherapy. The device provided reproducible information when infants were tested repeatedly over 30 minutes; the coefficient of variation for the transcutaneous bilirubin measurement was 3.1% around a mean estimate of 135.32 μmol/L (8.4 mg/dL). Conclusion. The Chromatics Colormate III allows for a clinically useful estimate of serum bilirubin in a wide variety of infants. By using a color discrimination algorithm and obtaining a skin measurement before the onset of icterus, this instrument can provide valuable clinical information that obviates the need for serum bilirubin determinations. Its use in newborn nurseries may allow physicians to shorten length of stay more safely and decrease the use of invasive blood tests.Keywords
This publication has 13 references indexed in Scilit:
- Susceptibility to Pre-Eclampsia Is Associated with Multiple Genetic Polymorphisms in Maternal Biotransformation EnzymesGynecologic and Obstetric Investigation, 2006
- Transcutaneous bilirubinometry in neonatal intensive care units.Archives of Disease in Childhood: Fetal & Neonatal, 1996
- Prediction and non‐invasive assessment of neonatal jaundice in the term healthy newborn infantActa Paediatrica, 1996
- Gestational Age Correlates with Skin Reflectance in Newborn Infants of 24–42 Weeks GestationNeonatology, 1993
- Effect of Skinfold Thickness on Transcutaneous Bilirubin MeasurementsNeonatology, 1993
- Measurement of the Yellow Colour of the Skin as a Test of Hyperbilirubinemia in Mature NewbornsActa Paediatrica, 1990
- The cephalocaudal progression of jaundice in newborns in relation to the transfer of bilirubin from plasma to skinEarly Human Development, 1990
- Skin colour and bilirubin in neonates.Archives of Disease in Childhood, 1989
- Transcutaneous Bilirubinometry: Serum Bilirubin Measurement using Transcutaneous Bilirubinometer (TcB)Neonatology, 1989
- Transcutaneous Bilirubin Monitoring of NewbornsAnnals of the New York Academy of Sciences, 1984