Bronchopleural Leakage Treated with Fibrin Sealant and High-Frequency Positive-Pressure Ventilation

Abstract
In a 62-year-old man, left spontaneous pneumothorax appeared 14 days after right pneumonectomy. The large air leakage necessitated thoracotomy and resection of a bullous area in the left upper lobe. Pleurectomy was not performed. The air leakage continued for 14 more days until, at a second left thoracotomy, numerous bullae were oversewn and covered with fibrin sealant. High-frequency positive-pressure ventilation (90 respirations/min, 21 l/min) was used for the following 6 hours. After 18 hours there was no more air leakage during spontaneous ventilation and the patient made a good recovery.

This publication has 4 references indexed in Scilit: