Abstract
Threshold intensity as a function of the duration of a tonal pulse was determined. A reciprocal determination was made of fixing the intensity level at specified points above reference threshold to measure the time threshold. The duration-intensity relationship revealed a marked dependency upon frequency; the differences observed were equivalent to the alteration of loudness function for the various test frequencies. A new measure of loudness increment degree, as well as conversion of db values into phon and sone values, indicated a close relationship between time threshold and loudness sensation. Therefore, the relationship between pulse duration and loudness level presents no artifacts reflecting frequency-dependent changes. The time threshold (T msec), as a fraction of pulse duration re the "adjusting time" of the auditory mechanism (150/T), seems to indicate the loudness of related levels above threshold in sones. General conclusions deriving from these relationships and some limitations of their applicability are discussed in detail; these are confirmed by a comparison between monaural and binaural time-threshold measurements.

This publication has 11 references indexed in Scilit: