Exact (spiral+circles) scan region-of-interest cone beam reconstruction via backprojection
- 1 May 2000
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 19 (5), 376-383
- https://doi.org/10.1109/42.870248
Abstract
We present a (spiral + circles) scan cone beam reconstruction algorithm in which image reconstruction proceeds via backprojection in the object space. In principle, the algorithm can reconstruct sectional region-of-interest (ROI) in a long object. The approach is a generalization of the cone beam backprojection technique developed by Kudo and Saito in two aspects: the resource-demanding normalization step in the Kudo and Saito's algorithm is eliminated through the technique of data combination that we published earlier, and the elimination of the restriction that the detector be big enough to capture the entire cone beam projection of the ROI. Restricting the projection data to the appropriate angular range required by data combination can be accomplished by a masking process. Because of the simplification resulting from the elimination of the normalization step, the most time-consuming operations of the algorithm can be approximated by the efficient step of line-by-line ramp filtering the cone beam image in the direction of the scan path, plus a correction image. The correction image, which can be computed exactly, is needed because data combination is not properly matched at the mask boundary when ramp filtering is involved. Empirical two-dimensional (2-D) point spread function (PSF) is developed to improve matching with the correction image which is computed with finite samplings. The use of transition region to further improve matching is introduced. The results of testing the algorithm on simulated phantoms are presented.Keywords
This publication has 6 references indexed in Scilit:
- Back-projection spiral scan region-of-interest cone beam CTPublished by SPIE-Intl Soc Optical Eng ,1999
- Cone-beam filtered-backprojection algorithm for truncated helical dataPhysics in Medicine & Biology, 1998
- Region-of-interest cone-beam CT with a spiral scanPublished by SPIE-Intl Soc Optical Eng ,1998
- Exact cone beam CT with a spiral scanPhysics in Medicine & Biology, 1998
- Derivation and implementation of a cone-beam reconstruction algorithm for nonplanar orbitsIEEE Transactions on Medical Imaging, 1994
- Practical cone-beam algorithmJournal of the Optical Society of America A, 1984