Abstract
The purpose of this study is to calculate basic dosimetry data for a CSM11 low dose rate 137Cs source in water. This source is widely used in afterloadable dome cylinders designed to homogeneously irradiate the vaginal cuff alone or additional areas of the vagina in hysterectomized patients. In this study, the Monte Carlo simulation code GEANT, incorporating in detail source geometry, is used to investigate the dosimetric characteristics of the source. The calculated data were analyzed using a fitting procedure that is described in detail. Absolute dose rate distributions in water were calculated around this source and are presented as conventional 2D Cartesian lookup tables (classically along-away tables). Also, the dose calculation formalism endorsed by the Interstitial Collaborative Working Group and the AAPM Task Group 43 have been calculated. The calculated dose rate constant for this source is lambda = 1.096 +/- 0.002 cGy h(-1) U(-1). The anisotropy function results in about 50% deviations from isotropy at positions near the long axis of the source. The radial dose function is given as a polynomial that reproduces the calculated data up to 20 cm. Best-fit values of attenuation coefficients suitable for use in Sievert integral calculations have been derived.Keywords
This publication has 17 references indexed in Scilit:
- Monte Carlo calculations of dose rate distributions around the Amersham CDCS-M-type 137Cs sourceMedical Physics, 2000
- Assessment of the relative dose distribution around an line source using a liquid ionization chamberMedical Physics, 1999
- Monte Carlo calculation of dose rate distributions around 0.5 and 0.6 mm in diameter wiresMedical Physics, 1999
- Code of practice for brachytherapy physics: Report of the AAPM Radiation Therapy Committee Task Group No. 56Medical Physics, 1997
- Monte Carlo calculation of dose rate distributions around wiresMedical Physics, 1997
- Experimental validation of Monte Carlo dose calculations about a high-intensity Ir-192 source for pulsed dose-rate brachytherapyMedical Physics, 1995
- Dosimetric characteristics, air-kerma strength calibration and verification of Monte Carlo simulation for a new ytterbium-169 brachytherapy sourceInternational Journal of Radiation Oncology*Biology*Physics, 1994
- Pair, Triplet, and Total Atomic Cross Sections (and Mass Attenuation Coefficients) for 1 MeV-100 GeV Photons in Elements Z=1 to 100Journal of Physical and Chemical Reference Data, 1980
- Minicolpostats, dome cylinders, other additions and improvements of the fletcher-suit afterloadable system: Indications and limitations of their useInternational Journal of Radiation Oncology*Biology*Physics, 1980
- Die Intensitatsverteilung der primaren γ-Strahlung in der Nahe medizinischer RadiumpraparateActa Radiologica, 1921