Visual performance and biocompatibility of 2 multifocal diffractive IOLs
- 1 August 2007
- journal article
- research article
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 33 (8), 1419-1425
- https://doi.org/10.1016/j.jcrs.2007.05.010
Abstract
To evaluate the distance and near functional capacity, wavefront error and biocompatibility in patients with 2 diffractive multifocal intraocular lenses (MIOLs). Ophthalmology Department of Chieti-Pescara University (Italy). This prospective study comprised 28 eyes of 28 senile cataract patients having phacoemulsification and implantation of the Tecnis ZM900 MIOL (Group 1) and the AcrySof ReSTOR MIOL (Group 2). The main outcome measures, over a 6-month follow-up period, were spherical equivalent, distance visual acuity at high and low contrast, near visual acuity, and defocus curve. Wavefront error was evaluated in both groups. Capsule opacification was also assessed. The high and low contrast uncorrected and best corrected visual acuity for distance did not show statistically significant differences between the 2 groups. The distance corrected near visual acuity was 1.86 +/- 1.66 in Group 1 and 1.93 +/- 1.12 in Group 2. The depth of focus was 4.5 diopters in both groups. The root mean square of total aberration and of spherical and coma aberrations were significantly lower in Group 1 than in Group 2. A higher percentage of patients with Tecnis MIOLs showed a more severe grade of anterior fibrosis. Posterior opacification was minimal and not significantly different between the 2 groups. Diffractive MIOLs were effective in improving functional capacity for distance and near and provided a good quality of vision due to a significant reduction in spherical aberration, particularly in the Tecnis MIOLs. The higher capsular biocompatibility of the ReSTOR MIOL compared with the Tecnis MIOL could ensure long-term stability.Keywords
This publication has 27 references indexed in Scilit:
- Quality of vision after AMO Array multifocal intraocular lens implantationJournal of Cataract & Refractive Surgery, 2004
- Refractive outcomes after bilateral multifocal intraocular lens implantationJournal of Cataract & Refractive Surgery, 2004
- Visual performance with multifocal intraocular lensesOphthalmology, 2004
- Optical aberrations of intraocular lenses measured in vivo and in vitroJournal of the Optical Society of America A, 2003
- Multifocal Intraocular LensesPublished by S. Karger AG ,2002
- Contrast sensitivity and depth of focus with aspheric multifocal versus conventional monofocal intraocular lensCanadian Journal of Ophthalmology, 2001
- Cataract extraction with multifocal intraocular lens implantation: A multinational clinical trial evaluating clinical, functional, and quality-of-life outcomesOphthalmology, 2000
- Contrast sensitivity and glare disability by halogen light after monofocal and multifocal lens implantationBritish Journal of Ophthalmology, 2000
- Long-term visual results of bifocal intraocular lens implantationJournal of Cataract & Refractive Surgery, 1999
- Comparison of a diffractive bifocal and a monofocal intraocular lensJournal of Cataract & Refractive Surgery, 1996