Hearing Screening of High-Risk Newborns with Brainstem Auditory Evoked Potentials: A Follow-up Study
- 1 January 1984
- journal article
- research article
- Published by American Academy of Pediatrics (AAP) in Pediatrics
- Vol. 73 (1), 22-26
- https://doi.org/10.1542/peds.73.1.22
Abstract
Numerous techniques have been used in attempts to find a reliable and efficient screening method for determining auditory function in the newborn. The brainstem auditory evoked potential (BAEP) is the latest method advocated for that purpose. The BAEP was evaluated as a hearing screening test in 168 high-risk newborns between 35 and 45 weeks of conceptual age. Follow-up data were obtained after 1 year (mean 17.3 months) on 134 of the infants (80%). Normal hearing was defined as a reproducible response in both ears to a 25 dB normal hearing level (nHL) click stimulus; 21 infants (12.5%) failed the initial screening test. Follow-up on 19/21 infants revealed 18 infants with normal hearing and one infant with an 80 dB nHL bilateral hearing loss substantiated. One infant with an abnormal screening test died before retesting, and the other infant was lost to follow-up but had only a unilaterally abnormal BAEP. None of the infants with a normal BAEP screening study had evidence of hearing loss on retesting. Sensitivity of the BAEP was 100%, specificity was 86%, predictive value of a positive test was 5.26%, and the predictive value of a negative test was 100%. The incidence of significant hearing loss in our population was between 0.75% (1/134 infants) confirmed, and 2.24% (3/134 infants) including infants who failed screening but were lost to follow-up. The BAEP is a sensitive procedure for the early identification of hearing-impaired newborns. However, the yield of significant hearing abnormalities was less than predicted in other studies using BAEP for newborn hearing screening.Keywords
This publication has 1 reference indexed in Scilit:
- Brain stem–evoked response in neonatesAmerican Journal of Obstetrics and Gynecology, 1979