Influence of different supine body positions on blood pressure
- 1 December 2000
- journal article
- research article
- Published by Wolters Kluwer Health in Journal Of Hypertension
- Vol. 18 (12), 1731-1736
- https://doi.org/10.1097/00004872-200018120-00005
Abstract
Objectives To investigate the influence of different supine body positions on blood pressure measured by an ambulatory device. Design and methods Twenty hypertensive and 20 normotensive subjects of a tertiary hospital outpatient clinic participated. Blood pressure was measured with an ambulatory blood pressure device while lying in the back, left side, right side and abdominal positions. The distance between the antecubital fossa and sternum was measured in all four body positions. An expected blood pressure difference between the arm of measurement and the right atrium (i.e. the midsternum) was calculated for the different body positions. Results When blood pressure was measured in side position at the left arm in hypertensive subjects, the mean systolic and diastolic blood pressure differences (± SD) between the left arm in the lower position and in back position at the same arm were +5/+4 (8/6) mmHg. These differences were −14/−17 (6/4) mmHg for the left arm lying above heart level in side position. Values of the right arm in hypertensives and the measurement at both arms in normotensive subjects yielded similar differences. Conclusions Body and arm position can both significantly influence the ambulatory blood pressure and therefore the day-night difference. This comprises one of the main reasons for the moderate individual reproducibility of the blood pressure fall at night.Keywords
This publication has 12 references indexed in Scilit:
- Effects of insufficient sleep on blood pressure in hypertensive patients A 24-h studyAmerican Journal of Hypertension, 1999
- Reproducibility and clinical value of nocturnal hypotensionJournal Of Hypertension, 1998
- Influence of the arm position on intra-arterial blood pressure measurementJournal of Human Hypertension, 1998
- Accuracy of the SpaceLabs 90207 determined by the British Hypertension Society ProtocolJournal Of Hypertension, 1991
- The clinical significance of diurnal blood pressure variations. Dippers and nondippers.Circulation, 1990
- Change in posture during sleep causes errors in non-invasive automatic blood pressure recordingsJournal Of Hypertension, 1989
- Arm position as a source of error in blood pressure measurementClinical Cardiology, 1987
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986
- Influence of arm position on measurement of blood pressure.BMJ, 1984
- Effect of Vertical Displacement of the Arm on Indirect Blood-Pressure MeasurementNew England Journal of Medicine, 1964