Strategies for CT Radiation Dose Optimization
Top Cited Papers
- 1 March 2004
- journal article
- review article
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 230 (3), 619-628
- https://doi.org/10.1148/radiol.2303021726
Abstract
Recent technologic advances have markedly enhanced the clinical applications of computed tomography (CT). While the benefits of CT exceed the harmful effects of radiation exposure in patients, increasing radiation doses to the population have raised a compelling case for reduction of radiation exposure from CT. Strategies for radiation dose reduction are difficult to devise, however, because of a lack of guidelines regarding CT examination and scanning techniques. Various methods and strategies based on individual patient attributes and CT technology have been explored for dose optimization. It is the purpose of this review article to outline basic principles of CT radiation exposure and emphasize the need for CT radiation dose optimization based on modification of scanning parameters and application of recent technologic innovations.Keywords
This publication has 65 references indexed in Scilit:
- Standard-Dose and 50%—Reduced-Dose Chest CT: Comparing the Effect on Image QualityAmerican Journal of Roentgenology, 2002
- Multi-Slice CT-Colonography in Low-Dose Technique - Preliminary ResultsRöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren, 2002
- CT scanning: patterns of use and doseJournal of Radiological Protection, 2000
- Unenhanced Helical CT Using Increased Pitch for Suspected Renal Colic: An Effective Technique for Radiation Dose Reduction?Journal of Computer Assisted Tomography, 2000
- Low-Dose Spiral Computed Tomography of the ThoraxInvestigative Radiology, 1998
- Reducing data size and radiation dose for CT colonography.American Journal of Roentgenology, 1997
- Effektivität der Bleiabdeckung zur Dosisreduktion beim Patienten in der ComputertomographieRöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren, 1996
- Das „Smart-Scan”-Verfahren der Spiral-Computertomographie: Eine neue Methode der DosisreduktionRöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren, 1996
- Anatomisch adaptierte Variation des Röhrenstroms bei der CTRöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren, 1995
- Optimal Processing of Computed Tomography Images Using Experimentally Measured Noise PropertiesJournal of Computer Assisted Tomography, 1979