Quantification of perfusion fMRI using a numerical model of arterial spin labeling that accounts for dynamic transit time effects
- 9 September 2005
- journal article
- clinical trial
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 54 (4), 955-964
- https://doi.org/10.1002/mrm.20613
Abstract
A new approach to modeling the signal observed in arterial spin labeling (ASL) experiments during changing perfusion conditions is presented in this article. The new model uses numerical methods to extend first‐order kinetic principles to include the changes in arrival time of the arterial tag that occur during neuronal activation. Estimation of the perfusion function from the ASL signal using this model is also demonstrated. The estimation algorithm uses a roughness penalty as well as prior information. The approach is demonstrated in numerical simulations and human experiments. The approach presented here is particularly suitable for fast ASL acquisition schemes, such as turbo continuous ASL (Turbo‐CASL), which allows subtraction pairs to be acquired in less than 3 s but is sensitive to arrival time changes. This modeling approach can also be extended to other acquisition schemes. Magn Reson Med, 2005.Keywords
This publication has 19 references indexed in Scilit:
- Fast, pseudo-continuous arterial spin labeling for functional imaging using a two-coil systemMagnetic Resonance in Medicine, 2004
- Analysis and Design of Perfusion-Based Event-Related fMRI ExperimentsNeuroImage, 2002
- Experimental Design and the Relative Sensitivity of BOLD and Perfusion fMRINeuroImage, 2002
- H215O PET validation of steady-state arterial spin tagging cerebral blood flow measurements in humansMagnetic Resonance in Medicine, 2000
- Correction for vascular artifacts in cerebral blood flow values measured by using arterial spin tagging techniquesMagnetic Resonance in Medicine, 1997
- Reduced Transit-Time Sensitivity in Noninvasive Magnetic Resonance Imaging of Human Cerebral Blood FlowJournal of Cerebral Blood Flow & Metabolism, 1996
- Quantification of relative cerebral blood flow change by flow‐sensitive alternating inversion recovery (FAIR) technique: Application to functional mappingMagnetic Resonance in Medicine, 1995
- NMR Measurement of Perfusion Using Arterial Spin Labeling Without Saturation of Macromolecular SpinsMagnetic Resonance in Medicine, 1995
- Magnetic resonance imaging of perfusion using spin inversion of arterial water.Proceedings of the National Academy of Sciences, 1992
- Perfusion imagingMagnetic Resonance in Medicine, 1992